Role of MRI in Breast Cancer Subtypes
- Conditions
- MRI in Breast Cancer
- Registration Number
- NCT06707584
- Lead Sponsor
- Lamiaa Gomaa Ahmed Elsayed
- Brief Summary
efficacy of MRI in detection of breast cancer molecular subtypes instead of biopsy and immunohistochemistry
- Detailed Description
2.4.4 -Study tools (in detail, e.g., lab methods, instruments, steps, chemicals, ...): Patient with breast cancer (malignant breast mass) will do MRI breast and molecular subtypes will be assessed
MRI imaging studies will performed on a 1.5 T scanner , The patient is placed in the prone position with both breasts placed adequately in a double breast coil (four-channel phased array coil), MRI sequences are:
1. Axial T1WI. 2. Axial T2WI. 3. Axial STIR. 4. DCE-MRI with post-processing subtraction images 5- Axial DWI at b value( 0, 400, 800 and 1000 mm\^2 per second) and ADC map will performed 6. MRI spectroscopy MRI acquisition protocol MRI protocols includes
* Axial T2-weighted fast spin echo sequence: TR=3840 ms, TE=81 ms, slice thickness=3.5 mm, and matrix=448×448.
* Coronal T2-weighted fast spin echo sequence: TR=3840 ms, TE=81 ms, slice thickness=3.5 mm, and matrix=448×448.s
* Short tau inversion recovery - axial: TR=8540 ms, TE=59 ms, TI=170 ms, slice thickness=3.5 mm, and matrix=320×314.4.
* The standard dynamic protocol commenced with a coronal three-dimensional rapid Field echo (thrive) sense non-enhanced T1-weighted sequence.
* A gadolinium containing contrast was administered at a dose of 0.2 ml/ kg by power injection at a speed of 2.0 ml/s and flushed with 20 ml of saline solution at the same rate.
* Dynamic imaging was then done in five consecutive series at 90-s intervals. Standard subtraction images were obtained by subtracting precontract images from the early peak postcontrast image.
Recruitment & Eligibility
- Status
- NOT_YET_RECRUITING
- Sex
- All
- Target Recruitment
- 45
a. patients with breast cancer confirmed by histopathology,
- breast implants
- general Contraindication of MRI as claustrophobia
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method accuracy of MRI in breast cancer subtyping 5 years To investigate the diagnostic accuracy of dynamic post contrast imaging MRI in evaluation of breast cancer molecular subtypes and DWI and ADC in detection of breast cancer molecular subtypes
- Secondary Outcome Measures
Name Time Method
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.