Effect of Two Years of Resistance Training in Cardiac Function in Older Women: a Randomized Controlled Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 64
- 试验地点
- 2
- 主要终点
- Doppler-echocardiography
研究概览
简要总结
Purpose: This study aimed to determine the effect of 48 weeks of resistance training (RT) on cardiac function in older women. Methods: Sixty-four older women (≥ 60 years), physically independent, were selected for this study. Participants were randomized into a training group (TG, n = 33) and a control group (CG, n = 31). The RT program was conducted over 48 weeks, three sessions a week, on nonconsecutive days, in the morning hours. Participants performed eight exercises for the whole body (chest press, horizontal leg press, seated row, leg extension, triceps pushdown, lying leg curl, preacher curl, seated calf raise) in three sets of 8-12 repetitions. The echocardiography was performed according to current guidelines before and after 48 weeks by an experienced echocardiographer blinded to patient status and group assignment. One-repetition maximum (1-RM) tests were used to analyze muscular strength. Glusoce, lipid profile, and C-reactive protein were measured. DEXA was used to measure body fat and muscle mass.
详细描述
Echocardiography exams were performed according to current guidelines, at baseline and the end of the study, by an experienced echocardiographer blinded to patient status and group assignment in a Philips ultrasound machine, model iE33 (Philips Medical Solutions, Noord Brabant, The Netherlands), equipped with S5-1 and X5-1 transducer. According to current recommendations, cardiac chamber dimensions, volumes, and left ventricular mass were measured. Mitral inflow velocities were assessed using pulsed-wave Doppler in the apical four-chamber view, with the sample volume placed between the tips of the mitral leaflets; velocities were recorded at end-expiration. Tissue Doppler velocities were acquired at end-expiration, in the apical four-chamber view, with the sample positioned at the septal and lateral mitral annulus for determination of systolic (S'), early diastolic (E'), and late diastolic (A') velocities. Pulsed wave Doppler velocities at the upper right pulmonary vein were also recorded. For all parameters, the average of three consecutive heartbeats was recorded.
Dietary intake - The 24-hour dietary recall method was used to analyze the participants' habitual intake throughout the study. Assessments were performed on three non-consecutive days of the week, in the first and last two weeks of each intervention phase. During the interviews, a photographic manual of food portion size was presented to the participants to improve the quality of food intake reports. Homemade measurements of the nutritional values of food were converted into grams and milliliters by the online software Virtual Nutri Plus (Keeple®, Rio de Janeiro, RJ, Brazil) for diet analysis. All foods not found in the program database were added to food tables.
Muscular strength Maximal dynamic strength was evaluated using one-repetition maximum (1RM) tests on the chest press, leg extension, and preacher curl exercises (Ipiranga Fitness, Presidente Prudente, SP, Brazil), respectively, following standard procedures 17,18. Three 1RM testing sessions were performed in the morning, separated by 48 h intervals. In each session, participants completed a warm-up of 10-15 repetitions before each exercise with approximately 50% of the estimated load to the first attempt, followed by three maximal attempts. For the first day of testing, the first selected load was based on the researchers' experience and perception of the difficulty (effort) with which participants performed the warm-up. If the first attempt was completed, the load was added for the subsequent attempts (3-10% of the previous effort). If an attempt was unsuccessful, load was removed in the same proportion. The rest period was three to five minutes between attempts and five minutes between exercises. The load for the first attempt in the second and third sessions was the maximal obtained in the previous session. Participants were encouraged to perform two repetitions with the selected load during each effort in the three exercises. The 1RM was recorded as the heaviest load lifted in which participants could complete only one voluntary muscle action among the three sessions. In addition, a total muscular strength score was calculated as the sum of the highest scores in each of the three exercises. Two experienced researchers supervised each exercise during testing sessions to standardize technique reliability and ensure the safety of participants.
Body composition. Dual-energy X-ray absorptiometry exams were performed in a Lunar Prodigy device, model NRL 41990 (General Electric, Madison, USA), to determine the total, regional lean soft tissue (LST), appendicular LST (ALST), and the total body, trunk, gynoid, and android fat masses. Participants were instructed to remove all metal objects before scanning to minimize possible estimation errors. Scans were performed with participants lying in the supine position along the table's longitudinal centerline axis. Feet were secured together at the toes to immobilize the legs while the hands were maintained in a pronated position within the scanning region. A skilled researcher carried out both calibration and analysis, following the manufacturer's recommendations. The software generated standard lines that separated the limbs from the trunk and head. The same technician adjusted these lines using specific anatomical points determined by the manufacturer and performed all analyses during the intervention. A predictive equation estimated total-body skeletal muscle mass from ALST.
Functional fitness tests - Four motor tests determined functional fitness: gait speed (4-m usual walking speed), walking agility, 30-s chair stand, and 6-min walk (6MWT). Three evaluators used stopwatches (KIKOS, São Paulo, SP, Brazil) to measure participants' time walking a 4-m usual walking speed. Adhesive tapes on the floor demarcated this distance with additional 2-m patches before and after the 4-m main patch. Participants walked 8-m, but only the time spent walking the middle 4-m was timed to the nearest 0.01 s. Participants completed three attempts, with the mean used for analysis. For the walking agility test, participants were seated on a chair supported by a wall, with their back in contact with the backrest, feet fully supported on the floor, and hands rested on the thighs. Participants were requested to stand up, walk around a cone at a distance of 2.44 m in front of the chair, return to the chair and sit down. Participants were instructed to complete the path as quickly as possible without running. Time was recorded to the nearest 0.01 s with a stopwatch from the initial movement to rise from the chair until returning to sit down again. Participants completed three trials, with the best one recorded for analysis. For the 30-s chair stand test, participants were seated on a chair supported by a wall, with their back in contact with the backrest, feet fully supported on the floor, and hands crossed to rest on their opposite shoulders. Participants performed the maximum sit-to-stand repetitions possible within 30 seconds. An evaluator recorded the time and counted the number of completed repetitions performed. For the 6MWT, each participant was instructed to walk as far as possible, without running, around a rectangular path (4.6 x 18.4 m, total perimeter: 46.0 m) marked with ribbons and cones on the floor for 6-min. An evaluator timed the test time, counted the number of laps, and calculated the total distance covered with an accuracy of one meter. The 6MWT assesses walking ability and endurance.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Prevention
- 盲法
- Single (Outcomes Assessor)
盲法说明
Assessor was blind to the primary outcome
入排标准
- 年龄范围
- 60 Years 至 —(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- •females aged ≥ 60 years; physically independent; had no cardiac, orthopedic, or musculoskeletal dysfunction that could impede physical exercise; not having uncontrolled diabetes mellitus or hypertension; and not be involved in the practice of regular physical activity performed more than once a week over the three months before the start of the study
排除标准
- •Not completed at least 80% of the sessions.
结局指标
主要结局
Doppler-echocardiography
时间窗: 48 weeks
Echocardiography exams were performed according to current guidelines, at baseline and the end of the study, by an experienced echocardiographer blinded to patient status and group. According to current recommendations, cardiac chamber dimensions, volumes, and left ventricular mass were measured. Mitral inflow velocities were assessed using pulsed-wave Doppler in the apical four-chamber view, with the sample volume placed between the tips of the mitral leaflets; velocities were recorded at end-expiration. Tissue Doppler velocities were acquired at end-expiration, in the apical four-chamber view, with the sample positioned at the septal and lateral mitral annulus for determination of systolic (S'), early diastolic (E'), and late diastolic (A') velocities. Pulsed wave Doppler velocities at the upper right pulmonary vein were also recorded. For all parameters, the average of three consecutive heartbeats was recorded.
次要结局
- Muscular strength(48 weeks)
- Gait speed test(48 weeks)
- Body composition(48 weeks)
- Dietary intake(48 weeks)
- walking agility test(48 weeks)
- 30-s chair stand test(48 weeks)
- triglycerides(48 weeks)
- low-density lipoprotein cholesterol (LDL-c)(48 weeks)
- 6-min walk (6MWT)(48 weeks)
- Serum levels of high-sensitivity C-reactive protein(48 weeks)
- Glucose(48 weeks)
- total cholesterol(48 weeks)
- high-density lipoprotein cholesterol (HDL-c)(48 weeks)
研究者
Edilson Serpeloni Cyrino
PhD