Ascension® Post- Approval Study; PyroCarbon Metacarpophalangeal Total Joint Prosthesis
- Conditions
- Systemic Lupus ErythematosusRheumatoid ArthritisPost-traumatic ArthritisOsteoarthritis
- Interventions
- Device: Ascension® MCP Finger Implant
- Registration Number
- NCT02408471
- Lead Sponsor
- Smith & Nephew, Inc.
- Brief Summary
This study is a non-randomized, consecutive enrollment, one-year post-approval study of patients who are treated with the Ascension® MCP.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- TERMINATED
- Sex
- All
- Target Recruitment
- 97
- Indications consistent with the FDA approved Indications For Use: Index, long, ring, or small finger metacarpophalangeal (MCP) joints that exhibit symptoms of pain, limited motion, or inadequate bony alignment (i.e., subluxation/dislocation) secondary to articular destruction or degenerative disease related to rheumatoid arthritis, systemic lupus erythematosus, osteoarthritis, or post-traumatic arthritis where soft tissue reconstruction can provide adequate stabilization
- Willing to participate in the study
- Signed an Informed Consent Form
- The means and ability to return for all required study visits
- Are not transient
Patients who have any of the following contraindications will be excluded from the study:
- Inadequate bone stock at the implantation site
- Active infection in the MCP joint
- Nonfunctioning and irreparable MCP musculotendinous system
- Physical interference with or by other prostheses during implantation or use
- Procedures requiring modification of the prosthesis
- Skin, bone, circulatory and/or neurological deficiency at the implantation site
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Ascension® MCP Finger Implant Ascension® MCP Finger Implant Single arm study, patient treated with Ascension® PyroCarbon MCP implant.
- Primary Outcome Measures
Name Time Method Number of Participants With Revisions 12 months Count of participants with a revision surgery.
- Secondary Outcome Measures
Name Time Method Change in Grip Strength Preoperatively to 12 months Implanted hand grip strength measured using a grip dynamometer instrument.
Change in Tip Pinch Preoperatively to 12 months Quantitative measurements of opposition tip pinch strength was made for each implanted digit. Measurements made using a pinch meter.
For each strength measurement, the participant made 3 attempts with the maximum value recorded.
If the participant could not perform the pinch test due to inflammation, excessive pain, or some other reason, DNA (which stands for "Did Not Attempt") was recorded. If the participant performs the pinch test but cannot register significant load, the value zero (0) was recorded.Function Visual Analog Scale (VAS) Preoperatively, 6 weeks, 12 weeks, 6 months, and 12 months VAS Function based on a scale of 0 to 100 as completed by the participant with 0 indicating worse function and 100 indicating normal function
Change in Joint Range of Motion Preoperatively to 12 months Range of motion measured by clinical assessment for joint extension and joint flexion. Measurements of extension and flexion made and recorded to the nearest degree using a goniometer with the wrist in the neutral position. Extension measured with fingers actively extended and flexion measured after the participant made a fist.
Change in Radial-Ulnar Deviation Preoperatively to 12 months Measurements of ulnar deviation made for each implanted metacarpophalangeal (MCP) joint. Measurements made to the nearest degree using a goniometer with the participant's wrist in a neutral position and the finger(s) fully extended (e.g., no extension deficit). Radial deviation or ulnar deviation direction checked.
Joint Position Preoperatively, 6 weeks, 12 weeks, 6 months, and 12 months Joint position for the affected finger determined by radiographic evaluation. Standard anteroposterior (AP), oblique, and lateral radiographs were made at the pre-operative and all post-operative evaluation visits of the hand(s) in which the Ascension MCP device was implanted. Joint position was classified as reduced, subluxed, dislocated, or (data) missing.
Component Migration 6 Weeks, 12 Weeks, 6 Months, 12 Months Component migration determined by radiographic assessment. Migration of the device was classified as none, yes, or (data) missing.
Joint Pain Visual Analog Score (VAS) Preoperatively, 6 Weeks, 12 Weeks, 6 Months, 12 Months VAS Joint Pain based on a scale of 0 to 100 as completed by the participant with 0 indicating no pain and 100 indicating severe pain.
Cosmetic Appearance Visual Analog Scale (VAS) Preoperatively, 6 Weeks, 12 Weeks, 6 Months, and 12 months VAS Cosmetic Appearance based on a scale of 0 to 100 as completed by the participant with 0 indicating worst appearance and 100 indicating normal appearance.
Bone Changes by Device 6 Weeks, 12 Weeks, 6 Months, 12 Months X-rays were examined to determine if the implant components demonstrate stable fixation in the bone. Bone changes were classified as no changes (i.e., none), any bone changes, or (data) missing.
Trial Locations
- Locations (9)
Fondren Orthopedic Group, L.L.P.
🇺🇸Houston, Texas, United States
Bloomington Bone and Joint Clinic
🇺🇸Bloomington, Indiana, United States
Mayo Clinic Rochester
🇺🇸Rochester, Minnesota, United States
Southwest Shoulder Elbow and Hand Center, P.C.
🇺🇸Tucson, Arizona, United States
Reconstructive Hand Surgeons of Indiana
🇺🇸Carmel, Indiana, United States
The Indiana Hand Center
🇺🇸Indianapolis, Indiana, United States
ROC Houston, PA
🇺🇸Houston, Texas, United States
The Center for Ortho/ Neuro Care & Research
🇺🇸Bend, Oregon, United States
The Hand Center of San Antonio
🇺🇸San Antonio, Texas, United States