MedPath

Safety of Overestimation of a Meal Insulin Bolus in the Context of Dual-hormone Closed-loop Operation

Phase 2
Completed
Conditions
Type 1 Diabetes
Interventions
Other: Dual-hormone closed-loop
Device: Dexcom G4 Platinum glucose sensor
Device: Accu Chek Combo insulin pump
Registration Number
NCT02626936
Lead Sponsor
Institut de Recherches Cliniques de Montreal
Brief Summary

In previous studies, investigators have studied if a pre-meal insulin bolus based on estimated carbohydrate meal size would alleviate the burden of carbohydrate counting without a significant degradation in postprandial glucose control. With this strategy, the patient would only have to evaluate the size of the meal in terms of carbohydrate (snack, regular, large or very large) It is however important to establish safety of this simplified meal bolus approach. The safety of overestimating a meal insulin bolus in the context of single and dual-hormone CLS with the simplified meal strategy needs to be determined. Computer simulation will be used to get a reasonable estimate of risks related to over-estimation with single-hormone closed-loop while over-estimation with dual-hormone closed-loop will be tested in adults with type 1 diabètes

Investigators hypothesize that dual-hormone closed-loop with overestimated meal size bolus will not increase time below 4.0 mmol/L compared to dual-hormone closed-loop with an adequately estimated meal size bolus

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
10
Inclusion Criteria
  1. Males and females ≥ 18 years old.
  2. Clinical diagnosis of type 1 diabetes for at least one year.
  3. The subject will have been on insulin pump therapy for at least 3 months and currently using a fast actin insulin analog (Lispro, Aspart or Guilisine).
  4. Last (less than 3 months) HbA1c ≤ 10%.
  5. Currently using carbohydrate counting as the meal insulin dose strategy.
Exclusion Criteria
  1. Clinically significant microvascular complications: nephropathy (estimated glomerular filtration rate below 40 ml/min), neuropathy (especially diagnosed gastroparesis) or severe proliferative retinopathy as judged by the investigator.
  2. Recent (< 3 months) acute macrovascular event e.g. acute coronary syndrome or cardiac surgery.
  3. Pregnancy.
  4. Severe hypoglycemic episode within 1 month of screening.
  5. Agents affecting gastric emptying (Motilium®, Prandase®, Victoza®, Byetta® and Symlin®) as well as oral anti-diabetic agents (Metformin, SGLT-2 inhibitors and DPP-4 inhibitors) if not at a stable dose for 3 months. Otherwise, these medications are acceptable and will be kept stable during the entire protocol.
  6. Oral steroids unless patients present a low stable dose (e.g. 10 mg or less of prednisone per day or physiological doses, less than 35 mg/day, of hydrocortisone Cortef®). Inhale steroids at stable dose in the last month are acceptable.
  7. Other serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator (e.g. unstable psychiatric condition).
  8. Failure to comply with team's recommendations (e.g. not willing to change pump parameters, follow algorithm's suggestions, etc).

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Arm && Interventions
GroupInterventionDescription
Dual-hormone CL with adequate estimation of meal size categoryAccu Chek Combo insulin pumpA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be adequately estimated, which will result in a meal insulin bolus for a meal of 65g of carbohydrates.
Dual-hormone CL with adequate estimation of meal size categoryDual-hormone closed-loopA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be adequately estimated, which will result in a meal insulin bolus for a meal of 65g of carbohydrates.
Dual-hormone CL with overestimation of meal size categoryDual-hormone closed-loopA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be overestimated by one category, which will result in a meal insulin bolus for a meal of 95g of carbohydrates.
Dual-hormone CL with overestimation of meal size categoryAccu Chek Combo insulin pumpA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be overestimated by one category, which will result in a meal insulin bolus for a meal of 95g of carbohydrates.
Dual-hormone CL with overestimation of meal size categoryGlucagonA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be overestimated by one category, which will result in a meal insulin bolus for a meal of 95g of carbohydrates.
Dual-hormone CL with overestimation of meal size categoryDexcom G4 Platinum glucose sensorA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be overestimated by one category, which will result in a meal insulin bolus for a meal of 95g of carbohydrates.
Dual-hormone CL with adequate estimation of meal size categoryDexcom G4 Platinum glucose sensorA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be adequately estimated, which will result in a meal insulin bolus for a meal of 65g of carbohydrates.
Dual-hormone CL with adequate estimation of meal size categoryInsulinA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be adequately estimated, which will result in a meal insulin bolus for a meal of 65g of carbohydrates.
Dual-hormone CL with overestimation of meal size categoryInsulinA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be overestimated by one category, which will result in a meal insulin bolus for a meal of 95g of carbohydrates.
Dual-hormone CL with adequate estimation of meal size categoryGlucagonA large size standardized meal of 75g of carbohydrates will be provided to the patient and the meal size will be adequately estimated, which will result in a meal insulin bolus for a meal of 65g of carbohydrates.
Primary Outcome Measures
NameTimeMethod
Percentage of time below 4.0 mmol/LThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Secondary Outcome Measures
NameTimeMethod
Mean glucoseThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Percentage of time of glucose concentrations below 3.1 mmol/LThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Number of patients with at least one hypoglycemic event with or without symptomsThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Total insulin deliveryThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Percentage of time of glucose concentrations between 4.0 and 8.0 mmol/LThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Percentage of time of glucose concentrations between 4.0 and 10.0 mmol/LThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Total number of hypoglycemic event below 3.1 mmol/LThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Total carbohydrate intake for hypoglycemia correctionThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Area under the curve of glucose values below 4.0 mmol/LThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Area under the curve of glucose values below 3.1 mmol/LThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.
Total glucagon deliveryThe outcome measure will be calculated over the 4 hours following the breakfast meal given on the dual-hormone closed-loop intervention. The 4-hour period is from 9:00 to 13:00.

Trial Locations

Locations (1)

Institut de recherches cliniques de Montréal

🇨🇦

Montreal, Quebec, Canada

© Copyright 2025. All Rights Reserved by MedPath