NCT02852941
Completed
Not Applicable
Assessment of Volumetric Hemodynamic Parameters and Nutritional Status in Stable Renal Transplant Recipients
Medical University of Warsaw1 site in 1 country80 target enrollmentJuly 2016
Overview
- Phase
- Not Applicable
- Intervention
- Not specified
- Conditions
- Cardiac Output, Low
- Sponsor
- Medical University of Warsaw
- Enrollment
- 80
- Locations
- 1
- Primary Endpoint
- Assessment of cardiac index in Stable Renal Transplant Recipients
- Status
- Completed
- Last Updated
- 9 years ago
Overview
Brief Summary
Changes in volumetric hemodynamic parameters and fluid overload (Cardiac Index,Stroke Volume, Thoracic Fluid Content, Systemic Vascular Resistance) were measured using a impedance cardiography (ICG) (CardioScreen 1000 - Haemodynamic Measurement System, Medis. Ilmenau) in stable renal transplant recipients Nutritional status was measured by Tanita 418 Monitor.
Investigators
Łukasz Czyżewski
PhD
Medical University of Warsaw
Eligibility Criteria
Inclusion Criteria
- •give voluntary consent to participate in the study
- •functioning graft longer than 3 months to 10 years
- •no clinical cardiovascular disease during the 6 months preceding entry
- •stable graft function- glomerular filtration rate \> 30 ml/min/1.73 m2, creatinine concentration \<2.5 mg/dl
- •medical staff (medical doctors, nurses)
Exclusion Criteria
- •not meet the above criteria
- •episode of illness (for example: infection)
- •pregnancy
Outcomes
Primary Outcomes
Assessment of cardiac index in Stable Renal Transplant Recipients
Time Frame: 1 day
Measurement of cardiac index (l/min/m2)
Secondary Outcomes
- Assessment of Nutritional Status in Stable Renal Transplant Recipients(1 day)
- Assessment of Systemic Vascular Resistance Index in Stable Renal Transplant Recipients(1 day)
Study Sites (1)
Loading locations...
Similar Trials
Completed
Not Applicable
Changes in Volumetric Hemodynamic Parameters Induced by Fluid Removal on HemodialysisEnd Stage Renal Failure on DialysisBody Fluid RetentionImpedanceCardiac Output, LowNCT02485782Medical University of Warsaw48
Completed
Not Applicable
Pulse CONtour and BIoimpedance for Measurements of Stroke Volume During Changes in CARdiac PreloadHemodynamic, MonitoringAnesthesiaBlood PressureNCT04231656University Hospital, Lille30
Completed
Not Applicable
Hemodynamic Assessment APCO Monitor vs Crit Line for Renal Replacement RxRenal FailureHemodynamicsNCT00666003Baystate Medical Center26
Completed
Not Applicable
Evaluation of Fluid Volume in Patients With Refractory Hypotension (Fresh-ER)Undifferentated ShockNCT05101031Ivor Douglas50
Not yet recruiting
Not Applicable
â??Effects on blood pressure, pulse rate,degree of anaesthesia and analgesia in patients undergoing Caeserian section under lower dose of drug during Spinal Anaesthesiaâ??Health Condition 1: O82- Encounter for cesarean delivery without indicationHealth Condition 2: O- Medical and SurgicalCTRI/2021/12/038735Ramakrishna Mission Seva Pratisthan And Vivekananda Institute Of Medical Sciences