MedPath

NEIVATECH Virtual Reality-based System for Amblyopia

Not Applicable
Terminated
Conditions
Amblyopia
Interventions
Other: Active vision therapy sessions with the NEIVATECH Virtual Reality-based system
Registration Number
NCT04819386
Lead Sponsor
Increase-Tech
Brief Summary

The NEIVATECH system has been designed to provide binocular vision training to 7-15 year old amblyopic children by discriminating Gabor patches presented with different contrast to each eye as a perceptual learning task.

Detailed Description

Due to the global impact of amblyopia, there is a medical and social need, and at the same time, a clear market niche, for the design and development of new therapies that can improve recurrence rates and non-compliance with conventional treatments. In this sense, the aim of this single-arm, multicentre, prospective pilot study is to examine the safety, acceptability and clinical efficacy of a novel Virtual Reality-based system designed to provide binocular vision training to 7-15 year old amblyopic children complementing the concepts of perceptual learning and dichoptic training with a gamification approach.

Recruitment & Eligibility

Status
TERMINATED
Sex
All
Target Recruitment
20
Inclusion Criteria
  • Children aged between 7 and 15 years.
  • VA in the amblyopic eye < 0.1 logMAR units.
  • Interocular difference in VA ≥ 1 logMAR line.
  • Interocular difference in espherical equivalent ≥ 1 D.
  • Interpupillary distance (IPD) between 60.7 and 73.5 mm.
  • Use of best refractive correction for at least 2 months prior to inclusion.
  • Lack of response or therapeutic adherence to conventional occlusion therapy.
  • Willingness to attend all the active vision therapy sessions and/or visits of the study.
  • No history of previous treatment for amblyopia other than optimal refractive correction for at least 2 months prior to inclusion.
Exclusion Criteria
  • Active eye disease.
  • Previous ocular surgery.
  • BCVA in the amblyopic eye of ≥ 0.70 logMAR.
  • Presence of cognitive impairment or neurological or psychiatric disorders.
  • Presence of irregular cornea due to astigmatism or ectatic corneal disease.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Active groupActive vision therapy sessions with the NEIVATECH Virtual Reality-based system18 half-hour in-office active vision therapy sessions with the NEIVATECH Virtual Reality-based system
Primary Outcome Measures
NameTimeMethod
Change in distance best-corrected visual acuity (BCVA)Baseline - 1 month

ETDRS, logMAR scale, maximum -0.3 (best) and minimum 1.20 (worse)

Secondary Outcome Measures
NameTimeMethod
Change in near BCVABaseline - 1 month

ETDRS, logMAR scale, maximum -0.3 (best) and minimum 1.20 (worse)

Change in photopic contrast sensitivity function (CSF)Baseline - 1 month

CSV-1000 test for spatial frequencies of 3, 6, 12 and 18 cycles/degree

Trial Locations

Locations (2)

Vithas Medimar International Hospital

🇪🇸

Alicante, Spain

University Clinical Hospital of Valladolid

🇪🇸

Valladolid, Spain

© Copyright 2025. All Rights Reserved by MedPath