The investigators will conduct a stepped wedge cluster-randomized controlled trial in maternity care facilities in Uganda to evaluate the impact of the provision of a reliable light source on the quality of delivery care provided. The facility-level intervention is the installation of a "Solar Suitcase", a complete solar electric system providing essential lighting and power for charging phones and small medical devices and a fetal doppler. The intervention will be rolled-out sequentially to all facilities over two time periods, in a randomized order.
- Detailed Description
Ensuring universal access to electricity is essential for global development. In the health sector, lack of reliable light and electricity is a major challenge for health workers when conducting deliveries at night. However, there is very little evidence of the impact of improving access to reliable electrification at maternity facilities on the quality of maternity care they provide.
This stepped wedge cluster-randomized trial will evaluate the impact of a reliable light and electricity source - the "Solar Suitcase" - on outcomes of availability and brightness of light, the quality of maternal care provided, and health worker satisfaction. The study will take place in rural health facilities conducting deliveries in Uganda. The eligible facilities have either no connection to electricity or a modern light source or have reported to have very unreliable light (blackouts occur frequently).
The intervention is a "Solar Suitcase", provided by the non-governmental organization "We Care Solar". The Solar Suitcases are complete solar electric systems that provide essential lighting and power for charging phones and small medical devices. Data collection will include direct observation of deliveries during daytime and nighttime hours, as well as interviews with facility staff. The intervention will be implemented in about 30 facilities in a step process, whereby at each 'step', half of the facilities (selected randomly) will receive the intervention.
Data will be collected at three time points: a baseline period in which no facilities have received the intervention, a midline period in which the first group of facilities has received the intervention but the other half has not, and an endline period in which all facilities have received the intervention.
In addition, facility-level data will be collected at three time points over a 9-month period after the completion of the endline. This data will be used to monitor delivery and ANC volumes at facilities.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Female
- Target Recruitment
- 1268
- Pregnant women who are admitted for labor and delivery at participating facilities.
- Women aged 16 years or older.
- Pregnant women who present to participating facilities for abortion or abortion-related complications, miscarriage, ectopic pregnancy, antenatal or postnatal complications of pregnancy (not an observation of labor)
- Women who are immediately transferred to another hospital, or are taken straight to surgical theatre (limited or no period of observation possible)
- Women who deliver at home but are brought to the facility for any complication.
- Women who deliver outside the maternity ward or delivery area
- Women who deliver in ambulance while on the way to the facility (woman admitted in the facility for placenta removal)
- Women who have not given consent
- Health worker objects to the observation.
For eligibility of health facility:
Inclusion criteria:
- government health facilities level 2, 3, or 4
- are open 24 hours a day
- conduct deliveries at night
- have unreliable electricity (have either no source of electricity, or have only 1 functional source of electricity and experience blackouts at least several times a week and had power available only sometimes in the past week).
Exclusion criteria:
• facility already has a Solar Suitcase
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Primary Outcome Measures
Name Time Method Average brightness of room during labor and delivery as measured by observer recorded questionnaire up to 6 months after installation Scale is scored as 1: Very Bright; 2: Somewhat Bright; 3: Dim; 4: Pitch Black. Variable is binary indicator for "very bright" or "somewhat bright" throughout delivery
Satisfactory light source used for entire delivery as measured by observer recorded questionnaire up to 6 months after installation Satisfactory light source is a variable equal to 1 if observation occurs without daylight and facility is using grid, solar or functional generator and zero if using kerosene, candle, torch, etc. Variable is always equal to 1 during daylight.
Adequate Light as measured by observer recorded questionnaire up to 6 months after installation Binary variable equal to 1 if light is from a satisfactory source and is "bright" ("very bright" or "somewhat bright") for duration of delivery observation.
20-item quality of maternal care index of essential actions to be performed by provider during labor and delivery as measured by observer recorded questionnaire up to 6 months after installation Quality of care index is based on essential actions providers must perform during the course of labor and delivery, as described in Tripathi et al. (2015). Score is the fraction of 20 items, yielding a range of 0 to 1, with higher scores indicating better quality of maternal care.
6-item delays in care index as measured by observer recorded questionnaire up to 6 months after installation Index including:
i) Time between facility arrival and first contact with health worker (mins) ii) Time between facility arrival and first assessment (mins) iii) Time between delivery and uterotonic (mins) iv) Time between delivery and assessment of perineal and vaginal lacerations (mins) v) Time between delivery and drying baby with towel (mins) vi) Time between delivery and initiation of breastfeeding (mins) Score is average of the 6 items measured in minutes, with lower values indicating reduced delays in quality of maternal care. Range from 0 to 120 minutes.37-item quality of maternal care index of essential actions to be performed by provider during labor and delivery as measured by observer recorded questionnaire up to 6 months after installation Quality of care index is based on the essential actions providers must perform during the course of labor and delivery, derived from the Maternal and Child Health Integrated Program (MCHIP). It includes the 20 items from Tripathi et al. (2015) plus an additional 17 quality of care items from MCHIP (2013). Score is fraction of the 37 items, yielding a range of 0 to 1, with higher scores indicating better quality of maternal care.
Health Worker Satisfaction with Electricity as measured by health worker survey up to 6 months after installation Responses on a 1-5 scale with 1: Strongly Disagree, 2: Disagree, 3: Neutral (Neither Agree nor Disagree), 4: Agree, 5: Strongly Agree
Worker Satisfaction with Electricity is a binary variable equal to 1 if strongly agree with both:
i) I am satisfied with the availability and brightness of light in this facility.
ii) I am satisfied with the availability of electricity in this facilityOverall job satisfaction index as measured by health worker survey up to 6 months after installation Responses on a 1-5 scale with 1: Strongly Disagree, 2: Disagree, 3: Neutral (Neither Agree nor Disagree), 4: Agree, 5: Strongly Agree
Overall job satisfaction index is the mean score (1-5) of the 4 below components:
i) These days, I feel motivated to work as hard as I can. ii) Overall, I am satisfied with my job. iii) Overall, the morale level at my department is good iv) I plan on staying at this position for the next year.
- Secondary Outcome Measures
Name Time Method Partograph Use as measured by observer recorded questionnaire up to 6 months after installation Provider starts partograph to monitor progress of labour. (binary)
Preparation of Uterotonic as measured by observer recorded questionnaire up to 6 months after installation Uterotonic is prepared for Active Management of the Third Stage of Labor (AMTSL). (binary)
Mean level of brightness over 4 periods of labor and delivery on brightness scale as measured by observer recorded questionnaire up to 6 months after installation Scale is scored as 1: Very Bright; 2: Somewhat Bright; 3: Dim; 4: Pitch Black
Phone availability as measured by observer recorded questionnaire up to 6 months after installation Phone is available and on for deliveries
Routine obstetric care signal functions as measured by facility assessment up to 6 months after installation Facility reported universal practice of routine obstetric care signal functions. Measure includes the number of signal functions performed from:
1. Infection control (provider hand-washing before patient exam in labor, new sterile gloves before every vaginal examination)
2. Use of partograph to monitor labor
3. Routine practice of active management of the third stage of laborTime between delivery and when suturing began (minutes) as measured by observer recorded questionnaire up to 6 months after installation Observed time between delivery and when provider began suturing lacerations, if needed.
Health Worker Assessment of Task Light Brightness as measured by health worker survey up to 6 months after installation Health worker response (1-5) on the following scale: 1: No procedure/task light; 2: Very poor; 3: Poor; 4: Good; 5: Very Good to the question: "In general, when the procedure/task light is on, how would you rate the quality of light (brightness) for maternal and newborn care (deliveries) in this facility at night?"
Consistent satisfactory light source as measured by observer recorded questionnaire up to 6 months after installation Variable equal to 1 if no interruptions of \> 2 hours in satisfactory light source during observed deliveries.
Fetal Doppler Use as measured by observer recorded questionnaire up to 6 months after installation Number of times the provider used a fetal doppler during labor and delivery
Basic emergency obstetric care signal functions as measured by facility assessment up to 6 months after installation Facility reported performance of basic emergency obstetric care signal functions in the past three months. Measure includes the number of signal functions performed from:
1. Removal of retained products of conception
2. Parenteral oxytocin for maternal hemorrhage
3. Parenteral magnesium sulfate for (pre-) eclampsia
4. Manual removal of placenta
5. Parenteral antibiotics for maternal infection
6. Assisted vaginal delivery10-item patient treatment index as measured by observer recorded questionnaire up to 6 months after installation Patient treatment/inter-personal quality care index, based on Kruk et al. (2014) including whether health worker: shouted/scolded patient, threatened to withhold treatment, ignored/left patient, did not answer questions, was not present when delivery began, slapped/beat mother, stitched episiotomy without anesthesia, demanded payment inappropriately, requested bribe, did not provide privacy to mother. Fraction of items that were NOT performed, yielding a range of 0-1, with higher scores indicating better treatment of patients.
14-item Partograph Completeness index as measured by observer recorded questionnaire up to 6 months after installation Index of variables (from MCHIP (2013) tool capturing completeness of recording on partograph). Fraction of 14 items completed on partograph (all binary variables), yielding a range of 0-1, with higher values indicating more completeness.
Sensor Brightness as measured by sensor up to 6 months after installation Recorded brightness at sensor sight in the two hours around delivery of baby.
Solar Suitcase Use for Deliveries as measured by enumerator recorded questionnaire up to 6 months after installation Fraction of deliveries in which enumerator recorded usage of suitcase
Minutes of delivery observation without satisfactory light as measured by observer recorded questionnaire up to 6 months after installation Satisfactory light source defined in Primary Outcome 2.
Routine newborn care signal functions as measured by facility assessment up to 6 months after installation Facility reported universal practice of routine newborn care signal functions. Measure includes the number of signal functions performed from:
1. Thermal protection (newborn dried immediately, skin-to-skin, no bath/delayed\>6 hours)
2. Exclusive breastfeeding initiated within 1 hour of birth
3. Hygienic cord care (cord cut with sterile blade/scissors; chlorhexidine or nothing applied to stump)Time between contractions as measured by observer recorded questionnaire up to 6 months after installation Time between contractions at first exam (mins)
Monthly Nighttime Delivery Volumes as measured by facility register up to 6 months after installation Average Number of Nighttime Deliveries per Month
Health Worker Assessment of Overhead Light Availability as measured by health worker survey up to 6 months after installation Health worker response (1-5) on the following scale: 1: No overhead light; 2: Very poor; 3: Poor; 4: Good; 5: Very Good to the question:
"In general, how would you rate the availability of overhead light for maternal and newborn care (deliveries) in this facility at night?"Health Worker Assessment of Task Light Availability as measured by health worker survey up to 6 months after installation Health worker response (1-5) on the following scale: 1: No procedure/task light; 2: Very poor; 3: Poor; 4: Good; 5: Very Good to the question:
"In general, how would you rate the availability of procedure/task light for maternal and newborn care (deliveries) in this facility at night?"Health Worker Assessment of Overhead Light Brightness as measured by health worker survey up to 6 months after installation Health worker response (1-5) on the following scale: 1: No overhead light; 2: Very poor; 3: Poor; 4: Good; 5: Very Good to the question: "In general, when the overhead light is on, how would you rate the quality of light (brightness) for maternal and newborn care (deliveries) in this facility at night?"
Communication with Patient as measured by observer recorded questionnaire up to 6 months after installation At least once, explains what will happen in labour to woman and/or her support person. (binary)
Assessment of Completeness of Placenta as measured by observer recorded questionnaire up to 6 months after installation Provider assesses completeness of the placenta and membranes. (binary)
APGAR Score Assigned as measured by observer recorded questionnaire up to 6 months after installation Provider assigns any APGAR score (binary variable equal to 1 if provider assigns an APGAR score (range of 0-10), and equal to 0 if no APGAR score is assigned.
4-item quality of suturing index as measured by observer recorded questionnaire up to 6 months after installation Index constructed from the following variables:
* Health worker explains to woman what is happening (binary)
* Health worker cleans area prior to suturing with antiseptic solution (binary)
* Health worker prepares instruments/sutures on a sterile surface (binary)
* Health worker sutures episiotomy or tears appropriately in layers. (binary) Score is fraction of 4 items, yielding a range of 0-1, with higher score indicating better quality of suturing.Dilation at first exam as measured by observer recorded questionnaire up to 6 months after installation Degree of dilation at woman's first exam (cm)
Monthly ANC Volumes as measured by facility register up to 6 months after installation Average Number of Antenatal Clients per Month
Monthly Referral Volumes as measured by facility register up to 6 months after installation Average Number of Monthly Referrals Out of Facility for Mothers and Newborns
Depletion of Solar Suitcase Battery Based on Voltage as measured by sensor up to 6 months after installation Average difference between solar suitcase load voltage in evening and morning (based on sensor)
Depletion of Solar Suitcase Battery Based on Charge Time as measured by sensor up to 6 months after installation Average time between morning and when the solar suitcase is fully charged, based on sensor
Takes Blood Pressure as measured by observer recorded questionnaire up to 6 months after installation Provider takes both systolic and diastolic blood pressure measurements of mother during initial exam (binary)
Cord Clamping as measured by observer recorded questionnaire up to 6 months after installation Provider ties or clamps cord. (binary)
Breastfeeding within 1 Hour as measured by observer recorded questionnaire up to 6 months after installation Breastfeeding is initiated within one hour of delivery. (binary)
Initial Exam: Previous Pregnancy Inquiry as measured by observer recorded questionnaire up to 6 months after installation Provider asks about complications during previous pregnancies. (binary)
Initial Exam Temperature Assessment as measured by observer recorded questionnaire up to 6 months after installation Provider takes mother's temperature during initial exam. (binary)
Basic emergency newborn care signal functions as measured by facility assessment up to 6 months after installation Facility reported performance of basic emergency newborn care signal functions in the past three months. Measure includes the number of signal functions performed from:
1. Antibiotics for preterm or prolonged PROM
2. Corticosteroids in preterm labor
3. Resuscitation with bag and mask for non-breathing baby
4. Kangaroo Mother Care for premature/very small babies
5. Alternative feeding if baby unable to breastfeed
6. Injectable antibiotics for neonatal sepsis
7. PMTCT if HIV-positive motherMonthly Delivery Volumes as measured by facility register up to 6 months after installation Average Number of Monthly Deliveries
Hand Washing as measured by observer recorded questionnaire up to 6 months after installation Provider washes his/her hands with soap and water or uses alcohol hand rub prior to every examination of woman. (binary)
14-item index of Health worker assessment of impact of blackouts on their ability to perform job functions as measured by health worker survey up to 6 months after installation Index of items measuring health worker assessment of impact of blackouts in facility on ability to conduct their job, including how often health worker: conducted deliveries without overhead light; had to hold torch in hand to see patient; experienced lack of light that affected normal care provided; delayed care; feared to move around facility; was affected in ability to suture, find/use equipment, conduct examinations of mother, provide emergency care, provide newborn care, monitor fetal heartrate, administer medication, clean up after delivery, manage infection control. Response to items scored (1-5) on following scale: 1. Every delivery, 2. Most, 3. Some, 4. Few, or 5. Never. Overall score measured as average of 14 items, yielding a range of 1-5.
Initial exam Bleeding Assessment as measured by observer recorded questionnaire up to 6 months after installation Provider asks whether woman has experienced vaginal bleeding during current pregnancy (binary)
Initial exam Headaches/Blurred Vision Assessment as measured by observer recorded questionnaire up to 6 months after installation Provider asks whether woman has experienced headaches and/or blurred vision during current pregnancy (binary)
HIV testing as measured by observer recorded questionnaire up to 6 months after installation Provider offers woman an HIV test or checks her HIV status (binary)
Takes Pulse as measured by observer recorded questionnaire up to 6 months after installation Provider takes pulse of mother during initial exam (binary)
Wears Sterile Gloves as measured by observer recorded questionnaire up to 6 months after installation Provider wears sterile gloves for initial vaginal exam (binary)
Assessment of Lacerations as measured by observer recorded questionnaire up to 6 months after installation Assesses completeness of the placenta and membranes. (binary)
Palpation of Uterus as measured by observer recorded questionnaire up to 6 months after installation Provider palpates uterus after delivery of placenta. (binary)
Initial Exam Fetal Presentation Assessment as measured by observer recorded questionnaire up to 6 months after installation Provider checks fetal presentation by palpation of abdomen. (binary)
Support of Perineum as measured by observer recorded questionnaire up to 6 months after installation Provider supports perineum after baby's head is delivered. (binary)
Cord Traction as measured by observer recorded questionnaire up to 6 months after installation Applies traction to the cord while applying suprapubic counter traction. (binary)
Hand Hygiene after Clean Up as measured by observer recorded questionnaire up to 6 months after installation Provider washes his/her hands with soap and water or uses alcohol hand rub after cleaning up. (binary)
Preparation of Bag and Mask as measured by observer recorded questionnaire up to 6 months after installation Prepares self-inflating ventilation bag and newborn face mask. (binary)
Administration of Oxytocin as measured by observer recorded questionnaire up to 6 months after installation After delivery, provider administers 10 IU of IM oxytocin, OR:
* 5 IU slow push if IV in place
* 600μg of misoprostol sublingually
* 600μg misoprostol rectally (binary)Skin-to-Skin as measured by observer recorded questionnaire up to 6 months after installation Provider places baby on mother's abdomen or chest skin-to-skin. (binary)
Drying Newborn as measured by observer recorded questionnaire up to 6 months after installation Provider immediately dries baby with towel. (binary)
Vital Signs Postpartum as measured by observer recorded questionnaire up to 6 months after installation Provider takes mother's vital signs after delivery. (binary)
Sterile Gloves for All Exams as measured by observer recorded questionnaire up to 6 months after installation Provider wears sterile gloves for all vaginal examinations. (binary)
Uterine Massage as measured by observer recorded questionnaire up to 6 months after installation Provider performs uterine massage immediately following the delivery of the placenta. (binary)
Initial Exam Fundal Height Assessment as measured by observer recorded questionnaire up to 6 months after installation Provider checks fundal height during initial exam. (binary)
Sterilization of Equipment as measured by observer recorded questionnaire up to 6 months after installation Provider sterilizes or uses high-level disinfection for all reusable instruments. (binary)
Waste Disposal as measured by observer recorded questionnaire up to 6 months after installation Provider disposes of all contaminated waste in leak-proof containers. (binary)
Delay in Facility Arrival as measured by observer recorded questionnaire up to 6 months after installation Time between facility arrival and first contact with health worker (mins)
Delay in Assessment for Lacerations as measured by observer recorded questionnaire up to 6 months after installation Time between delivery and assessment of perineal and vaginal lacerations (mins)
Initial Exam: Hand Washing as measured by observer recorded questionnaire up to 6 months after installation Provider washes his/her hands with soap and water or uses alcohol hand rub before initial examination. (binary)
Initial Exam: Vaginal Examination as measured by observer recorded questionnaire up to 6 months after installation Provider performs vaginal examination at initial exam. (binary)
Delay in Drying Newborn as measured by observer recorded questionnaire up to 6 months after installation Time between delivery and drying baby with towel (mins)
Initial Exam Fetal Heart Rate Assessment as measured by observer recorded questionnaire up to 6 months after installation Provider checks fetal heart rate with fetoscope/Doppler/ultrasound. (binary)
Preparation for Delivery: Cord ties/clamps and sterile scissors/blade as measured by observer recorded questionnaire up to 6 months after installation Prepares disposable cord ties/clamps AND sterile scissors/blade. (binary)
Newborn Temperature as measured by observer recorded questionnaire up to 6 months after installation Provider checks newborn's temperature. (binary)
Assistance with Breastfeeding as measured by observer recorded questionnaire up to 6 months after installation Provider assists mother with breastfeeding. (binary)
Delay in First Exam as measured by observer recorded questionnaire up to 6 months after installation Time between facility arrival and first assessment (mins)
Delay in Uterotonic as measured by observer recorded questionnaire up to 6 months after installation Time between delivery and uterotonic (mins)
Delay in Breastfeeding Initiation as measured by observer recorded questionnaire up to 6 months after installation Time between delivery and initiation of breastfeeding (mins)
Trial Locations
- Locations (1)
Innovations for Poverty Action
🇺🇬Kampala, Uganda
Innovations for Poverty Action🇺🇬Kampala, Uganda