Retinal Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography in Patients With Sleep Apnea Syndrome

Carmel Medical Center1 个研究点 分布在 1 个国家目标入组 166 人开始时间: 2007年9月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
166
试验地点
1
主要终点
Retinal Nerve Fiber Layer Thickness as measured Optical Coherence Tomography, and expressed in micrometers.

研究概览

简要总结

The purpose of this study was to measure the retinal nerve fiber layer (RNFL) thickness in eyes of Obstructive Sleep Apnea/hypopnea syndrome (OSAHS) using optical coherence tomography (OCT), and assess whether it is decreased. The investigators then compared the results with healthy subjects database of RNFL thickness from another retrospective study.

详细描述

An association between glaucoma and OSAHS has been reported in several studies. Glaucoma is a progressive optic neuropathy involving loss of retinal ganglion cells and their axons at the level of the optic nerve head.Computerized technologies have now been successfully used in evaluating retinal nerve fiber layer (RNFL) thickness in glaucoma.Given the evidence of a possible link between OSAHS and glaucoma, it is reasonable that structural losses in retinal nerve fiber layer (RNFL) thickness would be present in OSAHS.Indeed,decreased retinal nerve fiber layers was found in patients with OSAHS, the severity of which correlated with the severity of the patients' OSAHS using scanning laser Polarimetry (SLP).Optical coherence tomography (OCT) provides quantitative RNFL thickness data by measuring the difference in the temporal delay of back-scattered light from the RNFL and a reference mirror.During the past decade, OCT has been used widely in clinical practice to discriminate glaucomatous eyes and eyes with early perimetric glaucoma from normal eyes. Several studies confirmed the accuracy and reproducibility of the RNFL thickness measurements by OCT. The thickness of the peripapillary RNFL was measured with the Stratus OCT(Carl Zeiss Meditec, Inc, Dublin,CA)using the fast scan protocol(3.4).Only good quality images, as judged by the well-focused and centered scans,no artifacts showing distorted anatomy, no missing parts and a signal strength ≥6, were used for further analysis. The considered OCT parameters were overall average RNFL thickness and the average RNFL thickness in 4 quadrants (superior, nasal,inferior,and temporal)extracted from the standard RNFL thickness analysis report(RNFL Thickness Average Analysis Protocol).

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • formal diagnosis of moderate or severe OSAHS
  • eligibility to sign informed consent form
  • older than 18 years

排除标准

  • known glaucoma
  • not eligible to sign informed consent form
  • younger than 18 years
  • incompetent persons who lack decision making capability

结局指标

主要结局

Retinal Nerve Fiber Layer Thickness as measured Optical Coherence Tomography, and expressed in micrometers.

时间窗: four months

次要结局

未报告次要终点

研究者

发起方
Carmel Medical Center
申办方类型
Other
责任方
Principal Investigator
主要研究者

Orna Geyer

Professor

Carmel Medical Center