The Effect of Pneumoperitoneum on Intracranial Pressure in Pediatric Laparoscopic Surgery: Ultrasonographic Measurement of Optic Nerve Sheath Diameter
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 25
- 试验地点
- 1
- 主要终点
- ultrasonographic measurement of optic nerve sheath diameter
研究概览
简要总结
The pneumoperitoneum during laparoscopic surgery in pediatrics has the potential to cause an increase of intracranial pressure (ICP). Previous studies have proposed that ultrasonographic measurements of the optic nerve sheath diameter (ONSD) correlate with signs of increased ICP. Therefore, this study aims to confirm the increased ICP by ultrasonographic measurement of ONSD during laparoscopic surgery in pediatric patients.
研究设计
- 研究类型
- Observational
- 时间视角
- Prospective
入排标准
- 年龄范围
- — 至 9 Years(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •pediatric patients (under 9 yrs) scheduled for undergoing laparoscopic surgery under general anesthesia
排除标准
- •Patients with previous history of neurologic disease or neurosurgery, ocular disease or ocular surgery
结局指标
主要结局
ultrasonographic measurement of optic nerve sheath diameter
时间窗: change of ultrasonographic measurement of optic nerve sheath in 10 minutes after anesthesia induction, 10 minutes after pneumoperitoneum, and 10 minutes after CO2 desufflation.
A thick layer of gel is applied on the upper closed eyelid. The linear 13- to 6-MHz ultrasound probe is then placed in the gel, without exerting pressure on the eye. Two measurements are taken for each optic nerve: one in the transverse plane, with the probe being horizontal, and one in the sagittal plane, with the probe being vertical. The final ONSD is the mean of these measurements.
次要结局
未报告次要终点