Nitric Oxide Lung Diffusing Capacity in Healthy, Non-smoking Adults

Completed
Conditions
Healthy
Interventions
Device: Jaeger Masterscreen TM
Device: HypAir Medisoft
Registration Number
NCT04016597
Lead Sponsor
University of Zurich
Brief Summary

The measurement of nitric oxide lung diffusing capacity (DLNO) has been recently standardised. To date, two pulmonary function devices are commercially available and are used for the measurement of DLNO. No previous study assessed differences in gas exchange outcomes (e.g., DLNO values) between both devices.

The aim of this project is to compare two commercially available devices that measure lung diffusing capacity for nitric oxide (DLNO).

1. "MasterScreenTM" (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany

2. "HypAir" ("HA", Medisoft, Dinant, Belgium).

Detailed Description

In a single-center, crossover study conducted at the University Hospital Zurich, Switzerland, 35 healthy, non-smoking adults (\>=18 years) will be invited to perform DLNO measurements in random order using the MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium) devices during one study visit.

The order of the tests on the MasterscreenTM and HypAir devices will be randomly allocated using central randomisation.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
35
Inclusion Criteria
  • Age 18 years and older
Exclusion Criteria
  • Previous thoracic surgery
  • Smoking
  • Chronic lung disease (e.g., asthma bronchiale, COPD)
  • Forced expiratory volume in 1s and/or forced vital capacity below the lower limit of normal based on spirometry [Quanjer et al. Eur Respir J 2005]
  • Current respiratory infection

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Lung diffusing capacity measurementsHypAir MedisoftParticipants perform single-breath lung diffusing capacity measurements in random order during one study visit.
Lung diffusing capacity measurementsJaeger Masterscreen TMParticipants perform single-breath lung diffusing capacity measurements in random order during one study visit.
Primary Outcome Measures
NameTimeMethod
Difference in nitric oxide lung diffusing capacity (mL/min/mmHg)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Secondary Outcome Measures
NameTimeMethod
Difference in carbon monoxide lung diffusing capacity (mL/min/mmHg)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in inspiratory volume (L)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in expired concentrations for nitric oxide (in %)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in inspired concentrations for nitric oxide (in %)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in inspired concentrations for carbon monoxide (in %)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in expired concentrations for carbon monoxide (in %)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in inspired concentrations for oxygen (%)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in breath-hold time (s)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in expired concentrations for oxygen (%)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in Alveolar volume (L)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in inspired concentrations for helium (%)1 hour

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).

Difference in expired concentrations for helium (%)1 day

Single-breath measurements with MasterScreenTM (PFT Pro, Jaeger, CareFusion, Hoechberg, Germany) and HypAir (Medisoft, Dinant, Belgium).