跳至主要内容
临床试验/NCT05054192
NCT05054192Unknown不适用

Evaluation of Test-retest Reliability, Concurrent Validity and Minimal Detectable Change of the Modified Four Square Step Test in Individuals With Primary Total Hip Arthroplasty.

Afyonkarahisar Health Sciences University1 个研究点 分布在 1 个国家目标入组 28 人开始时间: 2021年9月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
28
试验地点
1
主要终点
Dynamic Balance

研究概览

简要总结

Functional improvements are reached in patients with primary total hip arthroplasty compared to the pre-operative term however some problems as continued range of motion limitations, loss of joint proprioception sensation, and resulting balance and gait disorders may result in failure of the Four Square Step Test. Therefore, the need for the apply of the Modified Four Square Step Test in individuals with primary THA is necessary. The aim of this study is to evaluate the test-retest reliability, concurrent validity and minimal detectable change of the Modified Four Square Step Test in individuals with primary total hip arthroplasty.

详细描述

Roos et al. improved the Modified Four-Square Step Test to complete the test by stroke patients and not to fall due to practices of the test while performing the test. The Modified Four Square Step Test variates from the The Four Square Step Test is that the person is not asked to look ahead during the test, and instead of using a cane, tapes are used to prevent people from losing their balance by tripping over the obstacle. Thus, although the height of the obstacle is reduced, the boundaries of the obstacle are preserved.

Functional improvements are reached in patients with primary total hip arthroplasty compared to the pre-operative term however some problems as continued range of motion limitations, loss of joint proprioception sensation, and resulting balance and gait disorders may result in failure of the Four Square Step Test. Therefore, the need for the apply of the Modified Four Square Step Test in individuals with primary THA is necessary. The aim of this study is to evaluate the test-retest reliability, concurrent validity and minimal detectable change of the Modified Four Square Step Test in individuals with primary total hip arthroplasty.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Prospective

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Being between the ages of 18-
  • Having undergone primary total hip arthroplasty at least ≥6 months ago.

排除标准

  • Having severe cardiovascular or lung disease
  • Having severe dementia or communication difficulties
  • Having a musculoskeletal or neurological problem that may affect participation in balance tests
  • Having an uncorrectable visual impairment
  • Having a body mass index of more than 40 kg/m2

结局指标

主要结局

Dynamic Balance

时间窗: 6 minutes

Dynamic balance is the ability of an object to balance while in motion or switching between positions. Dynamic balance will be evaluated with the modified four square step test. The duration as second will be recorded.

次要结局

  • Dynamic Balance(25 minutes)

研究者

发起方
Afyonkarahisar Health Sciences University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Emel Taşvuran Horata

PhD; Assistant Professor

Afyonkarahisar Health Sciences University

研究点 (1)

Loading locations...

相似试验