跳至主要内容
临床试验/CTRI/2024/06/068350
CTRI/2024/06/068350尚未招募不适用

Efficacy of novel EP technique of mask ventilation versus standard CE technique in obese patients for general anaesthesia

Lokmanya Tilak Municipal General Hospital and Medical CollegeSionMumbai1 个研究点 分布在 1 个国家目标入组 74 人开始时间: 2024年6月21日最近更新:

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
74
试验地点
1
主要终点
To determine the effectiveness of EP

研究概览

简要总结

Mask ventilation is the primary technique of ventilation before intubation or insertion of any airway devices during general anaesthesia.It is also a rescue technique for ventilation during unsuccessful attempts at intubation and difficult airway situations. There can be several factors contributing to inadequate mask ventilation that can be classified as patient related (such as beard, edentulous, thick neck),equipment related (inappropriate size mask ,non cushioned rim of the masks) or operator related factors (inexperience ,improper technique).

Airway management is more challenging in obese patients. They have impaired respiratory mechanics, decreased FRC and vital capacity ,increased airway resistance and reduced oxygen reserve. Maintaining airway  patency may be difficult in obese patients due to high collapsibility of upper airway structures and technical difficulty in applying the mask. Sustained effective mask ventilation becomes difficult in obese patient due to strain because of the heavy jaw and large neck circumference causing fatigue to the operator.

In order to tackle these difficulties we are studying an alternative novel technique which is a variant of VE technique named as EP technique. This technique provides a better seal and is an easy and strain free method than the standard CE technique that we use in mask ventilation .The CE technique applies the mask by forming a C shape with each thumb and index finger over each side of the mask while the third ,fourth and fifth fingers of both hands lift the mandible towards the mask in a three fingered E shape .In contrast, the EP technique uses each thumb over the mask which pushes the mask down to provide a better seal, while the second to fourth digits are along the mandible like an E that pull it upwards and the little finger behind the pinna for a better grip ,support and stability .This will not only improve the quality of ventilation ,ie, oxygenation and outcomes but also makes the operator fatigue free

研究设计

研究类型
Observational

入排标准

年龄范围
18.00 Year(s) 至 70.00 Year(s)(—)
性别
All

入选标准

  • Patients of more than 18 years whose BMI is more than 30 kg/m2.

排除标准

  • 1.Emergency surgery requiring RSI 2.Pregnant women.

结局指标

主要结局

To determine the effectiveness of EP

时间窗: at baseline

technique in obese adult population of mask ventilation in elective

时间窗: at baseline

and emergency surgeries as compared to standard CE technique

时间窗: at baseline

by evaluating the following parameters

时间窗: at baseline

1.Chest expansion(yes/no)

时间窗: at baseline

2.Capnography in numbers(35-40)

时间窗: at baseline

3.Inhaled and Exhaled Tidal Volume in ml

时间窗: at baseline

4.Peak airway pressure in mmhg

时间窗: at baseline

次要结局

  • To compare the failure rate of mask Ventilation for general anaesthesia by CE & EP technique(at baseline)

研究者

发起方
Lokmanya Tilak Municipal General Hospital and Medical CollegeSionMumbai
申办方类型
Government medical college
责任方
Principal Investigator
主要研究者

Dr Murshida U C

Lokmanya Tilak Municipal General Hospital and medical college

研究点 (1)

Loading locations...

相似试验