Comparison of Two Tests in the Assessment of the Accuracy of Esophageal Pressure Variations Measurement During Mechanical Ventilation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- Correct esophageal catheter balloon position
研究概览
简要总结
Esophageal pressure measurement, obtained with the use of an esophageal balloon catheter, is fundamental to assess mechanical characteristics of the respiratory system during mechanical ventilation. The correct positioning of the catheter (usually at the medium third of the esophagus) is crucial for an accurate measurement of esophageal pressure. Usually the correct positioning of the catheter is verified with an occlusion test (If the patient is breathing spontaneously) or with thoraco-abdominal compressions (if the patient is sedated and paralyzed). Aim of this study is to compare the accuracy of these two methods at different PEEP and esophageal catheter positions.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 90 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Mechanical ventilation for clinical purposes
排除标准
- •Hemodynamic instability
- •Esophageal diseases
- •Refusal of the patient
结局指标
主要结局
Correct esophageal catheter balloon position
时间窗: 10 minutes after the start of the study
次要结局
未报告次要终点
研究者
Davide Chiumello
MD
Policlinico Hospital