BICARbonate and Indirect Calorimetry Correlation in Critical Care

Hospices Civils de Lyon1 个研究点 分布在 1 个国家目标入组 91 人开始时间: 2026年11月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
91
试验地点
1
主要终点
Correlation coefficient between the CO₂ production/elimination mismatch assessed by indirect calorimetry and the change in blood bicarbonate over the study period.

研究概览

简要总结

Patients admitted to the intensive care unit frequently exhibit abnormal blood bicarbonate levels. These abnormalities are associated with patient outcomes and often prompt clinicians to modify management, either diagnostically or therapeutically (e.g., initiation or adjustment of mechanical ventilation, initiation or modification of extracorporeal renal replacement therapy, administration of specific diuretics, or sodium bicarbonate infusion).

Currently, the only way to determine blood bicarbonate concentration is through repeated blood sampling for laboratory analysis. However, this method is both discontinuous and invasive.

We have generated an in silico hypothesis suggesting that the mismatch between cellular CO₂ production/elimination and pulmonary CO₂ elimination reflects changes in blood bicarbonate levels. We propose to test this hypothesis in a cohort of intensive care unit patients.

If confirmed, indirect calorimetry could be positioned as a continuous, non-invasive monitoring tool for blood bicarbonate.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult patient admitted to the ICU within the past 72 hours
  • Receiving invasive mechanical ventilation
  • For whom the treating clinician plans to perform at least two blood bicarbonate measurements within the next 6 hours
  • No objection from the participant or their next of kin

排除标准

  • Planned weaning from invasive mechanical ventilation or ventilator change before the second bicarbonate measurement
  • Conditions interfering with the interpretation of indirect calorimetry data:
  • Inspiratory oxygen fraction > 60%
  • Administration of inhaled medications, including nitric oxide
  • Positive end-expiratory pressure (PEEP) > 15 cmH₂O
  • Excessive leaks in the ventilator circuit, defined as expired volume < 95% of inspired volume
  • Patient on mechanical circulatory support with a gas exchanger, or planned initiation before the second blood gas analysis
  • Patient on extracorporeal renal replacement therapy, or planned initiation before the second bicarbonate measurement
  • Patient who received sodium bicarbonate within 2 hours prior to inclusion, or planned administration before the second bicarbonate measurement
  • Frequent disconnections of the ventilator circuit, or planned bronchoscopy before the second bicarbonate measurement

结局指标

主要结局

Correlation coefficient between the CO₂ production/elimination mismatch assessed by indirect calorimetry and the change in blood bicarbonate over the study period.

时间窗: At day 1

CO₂ production/elimination mismatch is estimated using the indirect calorimetry, assuming that the respiratory quotient remains constant throughout the study. Change in blood bicarbonate is obtained using two consecutive arterial blood samples. This relationship will be assessed using Pearson's correlation coefficient if assumptions are met (normality and linearity); otherwise, Spearman's coefficient will be used. The correlation coefficient will be reported with its 95% confidence interval and p-value, and the relationship will be illustrated with a scatter plot and regression line or trend curve.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...