跳至主要内容
临床试验/NCT05172323
NCT05172323已完成不适用

Pre-procedural 3D Reconstructed Computer Tomography Versus Angiography Guided Percutaneous Coronary Intervention for Ostial Right Coronary Artery Lesions

Ziekenhuis Oost-Limburg2 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2022年1月13日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
2
主要终点
Geographical mismatch as quantified by intra-coronary ultrasound (IVUS)

研究概览

简要总结

Even with second generation drug eluting stents, rates of target lesion failure (TLF) for aorto-ostial RCA lesions remain high [3yrs TLF 14.2%]. Retrospective studies show that stent underexpansion and geographical stent-ostium mismatch are the main predictors for TLF. Geographical mismatch means that the stent is implanted either too distal (thereby not fully covering the lesion) or too proximal (thereby protruding too much in the aorta and hampering future engagement with guiding catheters). The investigators hypothesize that, pre-procedural 3D CT coronarography to determine the optimal C-arm angle of the X-ray system with the most accurate visualization of the aorto-ostial angle and determination of localization of calcium, could prevent geographical mismatch.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

盲法说明

The assessor of the IVUS images will be blinded to treatment arm

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Clinically indicated non-emergent PCI for an aorta-ostial-RCA lesion defined as a significant de novo lesion [by angiography or by physiological assessment] for which the operator intends to fully cover the ostial RCA with stent struts
  • Willing to provide informed consent

排除标准

  • Emergent PCI indication: if the ostial RCA lesion is the culprit lesion of an acute coronary syndrome [of note: if the ostial RCA lesion is a non-culprit lesion, patient can be included in the trial]
  • In-stent restenosis or thrombosis in the ostial RCA
  • Renal insufficiency [eGFR<30 ml/min]
  • Known allergic reaction to contrast medium

结局指标

主要结局

Geographical mismatch as quantified by intra-coronary ultrasound (IVUS)

时间窗: Procedural

Distance between the aorta-ostial junction and the most proximal protruding stent strut (in mm).

次要结局

  • Procedural radiation dose(Procedural)
  • Volume of contrast agent administered(Procedural)
  • Minimal luminal area (MLA)(Procedural)
  • Calcified lesions(Procedural)
  • Procedural duration from first puncture of artery to skin closure(Procedural)
  • Stent expansion(Procedural)
  • Stent sizing(Procedural)
  • Calcium modification(Procedural)
  • MACCE at 30 days follow-up(30 days after PCI)
  • Geographical mismatch as quantified by intra-coronary ultrasound (IVUS)(Procedural)

研究者

发起方
Ziekenhuis Oost-Limburg
申办方类型
Other
责任方
Principal Investigator
主要研究者

Koen Ameloot

Interventional cardiologist

Ziekenhuis Oost-Limburg

研究点 (2)

Loading locations...

相似试验

Pre-procedural 3DCT Versus Angiography Guided PCI... | 临床试验