跳至主要内容
临床试验/NCT00476320
NCT00476320已完成不适用

The Use of Myocardial Deformation Imaging Based on Ultrasonic Pixel Tracking to Identify Reversible Myocardial Dysfunction

RWTH Aachen University1 个研究点 分布在 1 个国家开始时间: 2004年8月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
试验地点
1

研究概览

简要总结

Myocardial deformation imaging allows analysis of myocardial viability in ischemic left ventricular dysfunction. This study will evaluate the predictive value of myocardial deformation imaging for improvement in cardiac function after revascularization therapy in comparison to contrast-enhanced cardiac magnetic resonance imaging (ceMRI).

In 55 patients with ischemic left ventricular dysfunction, myocardial viability was assessed using pixel-tracking-derived myocardial deformation imaging and ceMRI to predict recovery of function at 9±2 months follow-up. For each left ventricular segment in a 16-segment model peak systolic radial strain will be determined from parasternal 2D echocardiographic views and the amount of late hyperenhancement (LE) and maximal thickness of myocardial tissue without LE using ceMRI. The hypothesis is that compared with segments showing functional improvement, those that failed to recover had lower radial strain and lower thickness without LE and higher LE.

详细描述

Between August 2004 and June 2006 195 patients with ischemic left ventricular dysfunction underwent MRI for the definition of myocardial viability. Onehundred-ten patients with non-ischemic cardiomyopathy or acute coronary syndromes were excluded from the study to avoid possible acute ischemia or stunning. Within the 85 patients with chronic ischemic heart disease, six patients refused participation in this study and five patients had echocardiographic windows insufficient for participation. Within the remaining 74 patients 55 patients underwent revascularization and 19 had no revascularization. These 55 patients form our study group! Functional recovery will be assessed using echocardiographic images before and 9±2 months after revascularization with a Vivid Seven System (GE Vingmed, Horton, Norway). Parasternal long-axis and short-axis views at basal, midventricular and apical levels, as well as 3 standard apical views (4 chamber, 2 chamber, and long axis) have been acquired (frame rate 56 to 92 frames/s). Segmental wall motion will be determined using the following score: 1=normokinetic, 1.5= mildly hypokinetic, 2= moderately or severely hypokinetic, 3= akinetic, or 4= dyskinetic. A segment is considered to demonstrate functional improvement during follow-up if it improved by at least 1 grade. Global functional recovery was considered in case of an increase in ejection fraction>5% at follow-up.

The three acquired parasternal short axis views will be analysed with the aid of a dedicated software package (EchoPAC BT 05.2, GE Vingmed, Horton, Norway). This system allows analysis of peak systolic circumferential and radial strain from short axis views based on detection of natural acoustic markers. The system calculates mean strain values for whole predefined LV segments, including all myocardial layers from the endocardium to epicardium.

All patients underwent cMRI within a few hours of the baseline echocardiographic study on a 1.5-T whole-body MR scanner (Intera, Best, Philips, the Netherlands). The assignment to a hyperenhancement category reflects the extent of hyperenhancement within each segment by visual assessment considering a 5-group scale: 0% hyperenhancement (group 1), 1 to 25% hyperenhancement (group 2), 26 to 50% hyperenhancement (group 3), 51 to 75% hyperenhancement (group 4) and 76 to 100% hyperenhancement (group 5).

In addition, the maximal thickness of myocardial tissue without late hyperenhancement will be determined for each LV segment. This is considered to be a parameter of the remaining viable myocardium.

研究设计

研究类型
Observational
观察模型
Defined Population
时间视角
Other

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with ischemic left ventricular dysfunction scheduled for coronary revascularization

排除标准

  • Patients with acute coronary syndrome and poor echocardiographic windows

研究者

申办方类型
Other

研究点 (1)

Loading locations...

相似试验