跳至主要内容
临床试验/NCT04476342
NCT04476342Unknown不适用

Integration of Minimal Invasive Cardiopulmonary Bypass System and the Research of Its Blood Compatibility

Second Affiliated Hospital, School of Medicine, Zhejiang University1 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2019年6月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
80
试验地点
1
主要终点
Blood transfusion volume

研究概览

简要总结

Research objective:

(1) To develop a minimally invasive extracorporeal circulation integrated system, and to form a new product package, the package of the system should include the extracorporeal circulation off-set supplies for a routine heart operation.(2) To explore the influence of integrated minimally invasive extracorporeal circulation system on the recent clinical outcome of patients.(3) To explore the influence of integrated minimally invasive extracorporeal circulation system on blood dilution of patients.(4) To explore the influence of integrated minimally invasive extracorporeal circulation system on inflammatory response in patients.

1) Clinical research methods: A prospective, single-blind, randomized controlled study was designed. 80 patients should be included.Clinical study grouping: The control group was conventional cardiopulmonary bypass (CCPB) group, which was equipped with ordinary oxygenator, microemboli filter and 4:1 cardioplegia solution.The experimental group was minimal invasive cardiopulmonary bypass (MICPB) group, with built-in micro-thrombotic oxygenator and mini cardioplegia (MP) formula (15ML15% potassium chloride (KCl)+10ml compound potassium, calcium and magnesium +25ml normal saline).

Research method:

A: Before, in, and after cardiopulmonary bypass (CPB) blood collection, Hemoglobin (Hb), hematokrit (Hct), and blood lactate values of the two groups of patients were measured and analyzed statistically.B: Blood transfusion volume, urine volume and ultrafiltration volume were collected during CPB in the two groups of patients, and the data of the two groups were statistically analyzed.To investigate the effects of integrated minimally invasive extracorporeal circulation system on inflammatory response indicators white blood cell count (WBC),C-reactive protein (CRP), interleukin-6(IL-6), tumor necrosis factor-a (TNF-a) and C3a in patients before (T0), CPB (T1) and 2 hours(H) after CPB (T2), blood samples were collected from the two groups, centrifugated, superfluid was taken, and stored at -80℃.The concentrations of CRP, IL-6, TNF-a and C3a were determined by ELISA.Statistical analysis was performed.WBC was measured in blood routine.(3) To investigate the influence of integrated minimally invasive extracorporeal circulation system on the recent clinical outcome of patients. The mechanical ventilation time, ICU time, length of hospital stay, and in-hospital mortality of patients in the two groups were statistically analyzed.

详细描述

Research objective:

(1) To develop a minimally invasive extracorporeal circulation integrated system, and to form a new product package, the package of the system should include the extracorporeal circulation off-set supplies for a routine heart operation.(2) To explore the influence of integrated minimally invasive extracorporeal circulation system on the recent clinical outcome of patients.(3) To explore the influence of integrated minimally invasive extracorporeal circulation system on blood dilution of patients.(4) To explore the influence of integrated minimally invasive extracorporeal circulation system on inflammatory response in patients.

Research and development of integrated minimally invasive extracorporeal circulation system

(1) Appropriate CPB tubes should be determined according to clinical needs. Adopt 3/8 inch vein tubes and elevate the position of blood storage tank to reduce the length of the tubes and precharge.The piping jacket shall include the main pump pipe, the infusion pipe, the platform package (static and static vessels), the left and right core suction pipe, and the negative pressure suction pipe.The total precharge should be kept at about 800ml (284ml static precharge of the self-equipped micro-plug oxygenator, and about 500ml precharge of the pipeline and stopping liquid perfusion system).(2) Cooperate with integrated membrane oxygenator manufacturers in the design of pipelines to form a wrapper that integrates membrane oxygenator and pipeline.Among them, oxygenator and pipeline should be well connected in the sheath.

Clinical research methods:

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient weight ≤60kg;
  • Age ≥18 years old;
  • The patient underwent cardiac arrest surgery.

排除标准

  • Heart transplant patients;
  • Emergency cardiac surgery patients;
  • Patients who had been assisted by extracorporeal membrane oxygenator (ECMO) or assisted by left heart before operation
  • Left ventricular ejection fraction (LVEF) < 30%;
  • Patients with coagulation dysfunction before surgery;
  • Patients with preoperative hepatic and renal insufficiency;
  • Recent cerebrovascular accident patients.

结局指标

主要结局

Blood transfusion volume

时间窗: through surgery completion, an average of 5 hours

Blood transfusion volume during cardiac surgery

次要结局

  • ICU duration(Duration of ICU stay, an average of 3 days)

研究者

发起方
Second Affiliated Hospital, School of Medicine, Zhejiang University
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验