Pressure-Volume (PV) Measurements for Evaluating the Changes in the Ventricular Preload and Autonomic Nervous System Using BackBeat Medical Cardiac Neuromodulation Therapy (CNT) Signals in an Acute Study

BackBeat Medical Inc2 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2020年8月7日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
22
试验地点
2
主要终点
Effects of the Moderato CNT pacing signals on cardiac function

研究概览

简要总结

This investigation will evaluate the effect of RV pacing lead position on cardiac function and the modulation of the autonomic nervous system with Cardiac Neuromodulation Therapy (CNT) pacing signals. The study will be performed acutely prior to a pacemaker implant.

详细描述

Subjects indicated for a dual chamber pacemaker implant or replacement who are not 100% dependent on right ventricular pacing may be eligible to participate in the study.

This investigation will evaluate the effect of RV pacing lead position on cardiac function and the modulation of the autonomic nervous system using Cardiac Neuromodulation Therapy (CNT) pacing signals at different positions of the RV pacing lead.

A standard conductance catheter will be introduced through the femoral artery and advanced into the left ventricle to measure cardiac volumes and pressure.

Arterial blood pressure will be measured from the other femoral artery with an additional sheath.

The Moderato® IPG will be used to generate Cardiac Neuromodulation Therapy (CNT) signals and deliver them to the patient through the cable and leads. A range of CNT signal parameters will be used to assess the effect on sympathetic activity at different positions of the RV pacing lead. Ventricular pressure and volume readings from the conductance catheter and arterial pressure readings will be recorded and analyzed to assess the effect of CNT signals on cardiac function, sympathetic activity and blood pressure.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subject is ≥ 18 years of age
  • Subject requires implantation or replacement of a dual chamber pacemaker or requires an upgrade from a single chamber to a dual chamber pacemaker
  • Subject has known Hypertension
  • Subject is willing and able to comply with the study and procedures.

排除标准

  • Subject has symptoms of heart failure, NYHA Class II or greater
  • Subject has significant (>2+) mitral regurgitation, aortic regurgitation or aortic stenosis.
  • Subject has permanent atrial fibrillation
  • Subject has atrial fibrillation on the day of the study.
  • Subject has hypertrophic cardiomyopathy, restrictive cardiomyopathy or interventricular septal thickness ≥15 mm
  • Subject is on dialysis
  • Subject has a history of prior neurological events (stroke or TIA) within the past year or a neurological event (stroke or TIA) at any prior time that has resulted in residual neurologic deficit.
  • Subject has a history of autonomic dysfunction
  • Women who are pregnant or breast-feeding
  • Subject cannot or is unwilling to provide informed consent.

研究组 & 干预措施

Acute CNT pacing signals testing

Experimental

Acute study procedure will be carried out prior to a pacemaker implantation or replacement: pacemaker Right Atrial (RA) and Right Ventricular (RV) leads will be positioned according to standard procedure for pacemaker implant and connected to a Moderato® System IPG, via a single use, sterile Pacing System Analyzer (PSA) cable. The Moderato IPG will deliver CNT signals.

Furthermore, a standard conductance catheter in the left ventricle will measure cardiac volumes and pressure. Arterial blood pressure will be obtained as well.

A range of CNT signal parameters will be used to assess the effect on sympathetic activity at different positions of the RV pacing lead while ventricular pressure and volume and arteial pressure signals will be assesed for cardiac function, sympathetic activity and blood pressure. The effects of CNT signal over a range of parameter settings will be studied for the different RV lead positions.

干预措施: Moderato IPG's CNT pacing signals (Device)

Acute CNT pacing signals testing

Experimental

Acute study procedure will be carried out prior to a pacemaker implantation or replacement: pacemaker Right Atrial (RA) and Right Ventricular (RV) leads will be positioned according to standard procedure for pacemaker implant and connected to a Moderato® System IPG, via a single use, sterile Pacing System Analyzer (PSA) cable. The Moderato IPG will deliver CNT signals.

Furthermore, a standard conductance catheter in the left ventricle will measure cardiac volumes and pressure. Arterial blood pressure will be obtained as well.

A range of CNT signal parameters will be used to assess the effect on sympathetic activity at different positions of the RV pacing lead while ventricular pressure and volume and arteial pressure signals will be assesed for cardiac function, sympathetic activity and blood pressure. The effects of CNT signal over a range of parameter settings will be studied for the different RV lead positions.

干预措施: CD Leycom Pressure/Volume Combination Catheters (Device)

结局指标

主要结局

Effects of the Moderato CNT pacing signals on cardiac function

时间窗: approximately one hour

Left ventricular pressure (mmHg) and Volume (ml) will be obtained by a multisensor catheter which provides real-time, beat-to-beat intra-ventricular measurement of cardiac function and performance. Data will be used to generate Pressure-Volume Loops, an aknowledged way to describe hemodynamic changes. CNT signals (alternating short and long atrioventicular sequences 40-150 ms) will be delivered at the same by right ventricular pacemaker leads temporarely connected to the Moderato device.

Effects of CNT pacing signals on blood pressure

时间窗: aproximately onr hour

Blood pressure (mmHg) will be obtained in parallel with a Millar catheter from the femoral artery througout the study.