临床试验/NCT01623986
NCT01623986已完成不适用

Technical Correlation of a Noninvasive Estimation of Central Venous Pressure From the Mespere Venus 1000 System and the Inferior Vena Cava From Echocardiography, to Estimate Right Atrial Pressure

Mespere Lifesciences Inc.1 个研究点 分布在 1 个国家目标入组 45 人开始时间: 2013年3月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
45
试验地点
1
主要终点
Right atrial pressure (RAP)

研究概览

简要总结

The purpose of this clinical study is to investigate if central venous pressure (CVP) measurements from the Mespere Venus 1000 System can be used for right atrial pressure (RAP) when estimating right ventricular systolic pressure (RVSP) in echocardiography labs.

详细描述

The non-invasive assessment of the pressure on the right side of your heart using an imaging machine called a Doppler echocardiography machine (also known as an ECHO machine) is a widely accepted technique and is used as a screening tool for pulmonary hypertension and heart failure. The pressure on this side of your heart reflects the pressure of the blood in your veins returning to your heart and the effectiveness of your heart to pump that blood to your lungs. The accuracy of this technique depends on making an accurate estimate of the pressure in the upper chamber (atrium) of the right side of your heart, known as your right atrial pressure (RAP). Right atrium pressure can be measured non-invasively by imaging of your heart using an echocardiography (aka ECHO) machine. But the technique depends on the skills of the sonographer (the person who operates the ECHO machine) and can take considerable time to complete.

In view of this limitation, a non-invasive technique that could be used to make the RAP measurements may be more reliable and/or faster than the current technique.

Mespere Lifesciences Inc. has developed a new non-invasive device that is expected to allow for a simple, rapid and reliable measurement of RAP. The device consists of a set of light sensors on a patch that is placed onto the surface of the patient's right side of the neck.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 18 and older
  • Patient referred to St. Michael's Hospital Echocardiography Lab
  • Signed written and informed consent

排除标准

  • Lack of patient consent
  • Presence of known AV dialysis fistula
  • Allergy to adhesive tape from Mespere Venus 1000 system
  • Known central vein stenosis
  • Unable to identify right external jugular vein
  • Ongoing photodynamic therapy
  • Assisted ventilation

结局指标

主要结局

Right atrial pressure (RAP)

时间窗: 0-1 hour

To determine if the RAP from the non-invasive Mespere Venus 1000 System correlates with the RAP from an echocardiography (ECHO) machine

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (1)