Pulmonary Ultrasound to Evaluate Protective Lung Ventilation in Obese Patients With Postoperative Pulmonary Complications Impact

General Hospital of Ningxia Medical University1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2021年8月21日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
100
试验地点
1
主要终点
Lung ultrasound scoring

研究概览

简要总结

Peri - operative ultrasonography was used to evaluate the effects of protective lung ventilation on the postoperative lungs of obese patients.The purpose of this study was to apply ultrasound lung ventilation area score to the monitoring of pulmonary complications in patients with postoperative obesity.To verify the reliability and practicability of perioperative lung ultrasound quantitative scoring.

详细描述

Ultrasound lung ventilation area score was applied to monitor the pulmonary complications of patients after obesity operation to verify the perioperative period.

The reliability and practicability of quantitative lung ultrasound score to clarify the effect of protective lung ventilation under perioperative pulmonary ultrasound monitoring on obesity patients.To guide the management of mechanical ventilation under general anesthesia and the prevention and treatment of postoperative pulmonary complications

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • enrollment of patients aged 18 years or above;
  • Eligible adult patients had an American Society of Anesthesiologists (ASA) physical status classification of I to IV
  • undergoing elective or expedited nonurgent, noncardiac surgery with general anesthesia

排除标准

  • patient refusal;
  • morbid obesity (BMI >40 kg/ m²);
  • American Society of Anesthesiologists (ASA) physical status categories IV-V;
  • previous intrathoracic procedure;
  • severechronic obstructive pulmonary disease (forced expiratory volume in 1 s <30% of the predicted value;
  • a contraindication to radial artery cannulation.

结局指标

主要结局

Lung ultrasound scoring

时间窗: in the morning of the first day

Four signs were used in lung ultrasound scoring Lung ultrasound score: N (0): pleural line and A line, less than 3 B lines; B1 (1 mark): More than 3 B line; B2 (2 points): Fuse line B; C (3 points): Signs of lung consolidation. The higher the score is, the worse the pulmonary ventilation status is. When scoring, the sign with the greatest severity is taken as the score value of the examination area. There are 12 examination areas in both lungs, so we have a LUS The score is between 0 and 36

次要结局

  • Mechanical ventilation parameter(entering the operating room, in the morning of the first day ,the second day , the third day after surgery)
  • Results of arterial blood gas analysis(entering the operating room, in the morning of the first day ,the second day , the third day after surgery)