临床试验/NCT00788788
NCT00788788已完成1 期

PoC Study of Heliox With Helium-Fractions Between 25 and 75% in Experimental Upper Airway Obstruction

University of Witten/Herdecke1 个研究点 分布在 1 个国家目标入组 44 人开始时间: 2007年11月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
1 期
状态
已完成
入组人数
44
试验地点
1
主要终点
Dyspnea score

研究概览

简要总结

Currently it is common medical wisdom that HELIOX (mixture of Helium in Oxygen) with a fraction of Helium below 60% is not effective in reducing airway obstruction. The investigators test the hypothesis that HELIOX with a fraction of Helium below 60% is still effective in relieving airway obstruction in a double-blind, randomized and controlled clinical PoC study with experimental upper airway obstruction.

详细描述

HELIOX is a mixture of Helium and Oxygen. It is a therapeutic modality that can improve upper and lower airway obstruction. The lower density of Helium can help to relieve airway obstruction and is known to lower the work of breathing. The fraction of Helium (FHe) in HELIOX should be maximized (e.g. up to a fraction of 79% with 21% of oxygen added) in order to achieve optimal anti-obstructive outcome and according to the literature a FHe below 60% renders HELIOX ineffective.

Objective

We conducted an investigator-initiated trial using different mixtures of Helium and Oxygen in 44 healthy volunteers in a randomized and double-blinded fashion.

Methods: After an adjustment phase the subjects were breathing through two different external resistors (intratracheal tube with inner diameter of either 4.0mm or 5.0mm) while gas of different composition (medical air with 79% Nitrogen and 21% Oxygen as control gas and HELIOX with a fraction of either 25%, 50% or 75% Helium in Oxygen, respectively) was provided in a blinded and random fashion. A crossover design was used so that every subject was exposed to every HELIOX gas mixture. Subjects were asked to score their degree of dyspnea after breathing different gas mixtures for 2 minutes intervals. In addition the variability of different hemodynamic parameters was assessed (continuous non-invasive blood pressure (systolic, diastolic and mean blood pressure), impedance cardiography (stroke volume and cardiac output), ECG (heart rate variability)) were assessed non-invasively and used to detected a change in the degree of airway obstruction in respect to the added load and the gas mixture.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Volunteers of both sexes were recruited via posting in student forum of University of Witten/Herdecke
  • Willingness to spend about 2h in the clinical exp. lab.

排除标准

  • Acute airway infection
  • History of asthma
  • Pregnancy
  • Abnormal lab. screen with liver function tests, Creat./BUN, CBC, blood glucose
  • Anxiety or mood disorder
  • Any chronic disease (incl. lung & heart disease, cancer, endocrine disorder)
  • Mental retardation

研究组 & 干预措施

1

Active Comparator

Study subjects where breathing Heliox with a fraction of Helium of 25% followed by 50% and 75% with larger external resistor in comparison to medical air

干预措施: HELIOX (Drug)

2

Active Comparator

Study subjects where breathing Heliox with a fraction of Helium of 50% followed by 75% and 25% with larger external resistor in comparison to medical air

干预措施: HELIOX (Drug)

3

Active Comparator

Study subjects where breathing Heliox with a fraction of Helium of 25% followed by 50% and 75% with larger external resistor in comparison to medical air

干预措施: HELIOX (Drug)

结局指标

主要结局

Dyspnea score

时间窗: Minutes

Variability of systolic blood pressure

时间窗: Minutes

次要结局

未报告次要终点