跳至主要内容
临床试验/NCT05955222
NCT05955222已完成不适用

Clinical Performance Comparison of Different Occlusal Splint Materials: a Clinical Study

Istanbul University2 个研究点 分布在 2 个国家目标入组 24 人开始时间: 2020年2月2日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
24
试验地点
2
主要终点
Measurement of occlusal surface change

研究概览

简要总结

The goal of this clinical study is to compare the performance of computer aided designed and computer aided manufactured (CAD/CAM) occlusal splints with splints produced with conventional methods. The main questions this clinical study aims to answer are:

  • Do CAD/CAM splints have the same therapeutic effect as the traditional splints ?
  • Do CAD/CAM splints demonstrate better surface wear and fit and lower wear in opposing jaw than traditional splints ?
  • Is objective pain evaluation of the patient better with CAD/CAM splints ?

Participants were asked to use the splints for 6 months, 8 hours a day and come for follow-up appointments 3 times during this 6 month period:

  • Delivery appointment
  • First appointment: one week later after delivery appointment
  • Last appointment: 6 months after delivery appointment Researchers compared CAD/CAM groups with traditional group to see the clinical performance of the CAD/CAM groups.

详细描述

24 patients applying to Istanbul University Faculty of Dentistry Department of Prosthodontics and diagnosed with Diagnostic Criteria/ Temporomandibular Disorders (DC/TMD) protocol were included in the study. The patients were randomly divided into 3 groups (n=8); PEEK group (PEEKG), PMMA group (PMMAG), and control group (CG). Dental stone casts of the upper and the lower jaws of the patients were obtained by condensation type silicone impression material and occlusal splints were fabricated in study groups with digital method (designed and milled, manufactured with CAD/CAM) either from PEEK blocks or PMMA blocks and in control group with traditional vacuum pressing machine and adapted by the clinician at chairside. The patients wore the splints for 6 months. Surface roughness, surface wear, fit of the splints and patient satisfaction as well as therapeutic effect of the splints were examined.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

盲法说明

The patients will not know which group they are assigned. Also the clinician who is going to make the examinations before and after the study will not be aware of groups.

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients diagnosed with TMD according to DC/TMD
  • Aged between 18 and 65

排除标准

  • Patients with removable dentures
  • Patients diagnosed with Disc displacement without reduction according to DC/TMD
  • Patients receiving medication for psychological disorders
  • Patients diagnosed with systemic joint disorders
  • Patients who has received TMD treatment in the last 6 months

结局指标

主要结局

Measurement of occlusal surface change

时间窗: Baseline and 6 months

Amount of material loss on the occlusal surface of the splints were determined by superimposition of the scannings which were obtained at the base line and at the end of the study. The surfaces were scanned with a professional reference scanner (Solutionix C500 Optical 3D Measuring System,2018,South Korea) and the data obtained were aligned for the best fit algorithm and digital evaluations were performed with the Geomagic Control (2021,USA) software program with an accuracy of 0.001 mm. Surface abrasions were determined by superposition at 24 different predetermined points.

Pain change

时间窗: baseline and 6 months

Patients were examined according to DC/TMD (Diagnostic Criteria/ Temporomandibular Disorders) protocol and Clinical examination form of the DC/TMD protocol was used. The patients were examined before and after the treatment. The pain scores of masticatory muscles as well as pain during mandibular movements were recorded.

Measurement of the opposing teeth hard tissue change

时间窗: Baseline and 6 months

Hard tissue wear on opposing teeth were determined by superimposition of the casts of the patients which were obtained at the base line and at the end of the study. The cast models were scanned with a professional reference scanner (Solutionix C500 Optical 3D Measuring System,2018,South Korea) and the data obtained were aligned for the best fit algorithm. Evaluations were performed with the Geomagic Control (2021,USA) software program with an accuracy of 0.001 mm. Surface abrasions were determined by superposition at 30 different predetermined points.

Evaluation of the Fit of the splint

时间窗: Baseline

The cameo surfaces of the splints were scanned for the evaluation of integral accuracy of the splints and superimposed with the Standard Triangle Language (STL) data of dental arch. The maxillary cast models and the cameo surface of the occlusal splints were scanned with a professional reference scanner (Solutionix C500 Optical 3D Measuring System,2018,South Korea) and the data obtained were aligned for the best fit algorithm. Fit evaluations were performed with the Geomagic Control (2021,USA) software program with an accuracy of 0.001 mm. Surface abrasions were determined by superposition at 24 different predetermined points.

Subjective pain change

时间窗: baseline and 6 months

Patient's evaluations of their overall pain were with performed with VAS (Visual analogue scale). VAS scores ranges from 0 to 100 with the leftmost point indicating 'very poor' and the rightmost 'very good'. The patients were asked to report their pain before and after the treatment.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Bilge Gokcen-Rohlig

Professor Dr.

Istanbul University

研究点 (2)

Loading locations...