跳至主要内容
临床试验/NCT04777188
NCT04777188已完成不适用

Left Ventricular Systolic Function After Percutaneous Intramyocardial Septal Radiofrequency Ablation for Hypertrophic Obstructive Cardiomyopathy: a Study Focused on Speckle Tracking Echocardiography

Xijing Hospital1 个研究点 分布在 1 个国家目标入组 70 人开始时间: 2016年10月22日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
70
试验地点
1
主要终点
Left ventricular systolic function before and after Percutaneous Intramyocardial Septal Radiofrequency Ablation

研究概览

简要总结

Objective to investigate the left ventricular (LV) systolic function by speckle tracking echocardiography before and after percutaneous intramyocardial septal radiofrequency ablation for hypertrophic obstructive cardiomyopathy (HOCM).

Percutaneous intramyocardial septal radiofrequency ablation (named Liwen Procedure) is a safe and effective treatment approach for HOCM and results in sustained improvement in exercise capacity and persistent in reducing left ventricle outflow tract (LVOT) gradient. However, the systolic function of the myocardial after Liwen procedure in HOCM patients is not well exploration and research. Strain evaluation using speckle tracking echocardiography is an excellent tool for assessing regional and global LV functions.

In this study, the investigators aimed to characterize regional and global strain using speckle tracking echocardiography to assess LV radial, circumferential and longitudinal systolic myocardial function in patients with HOCM before and after Liwen procedure.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with symptoms that limit daily activities (New York Heart Association functional class >II, exercise-induced syncope) despite adequate medical treatment or when medical treatment is not tolerated
  • Patients with a peak LVOT gradient≥50 mm Hg

排除标准

  • Those with a peak instantaneous Doppler LVOT gradient of <50 mm Hg
  • Those with an indication for septal reduction therapy and other lesions requiring surgical intervention (e.g., mitral valve repair/replacement and papillary muscle intervention)
  • Those with end-stage heart failure;and those the echocardialology image quality is not clear enough for strain analysis.

结局指标

主要结局

Left ventricular systolic function before and after Percutaneous Intramyocardial Septal Radiofrequency Ablation

时间窗: 1 year

The left ventricular(LV) systolic function was analyzed by Tomtec Workstation with related software. LV was automatically divided into 16 segments using standard segmentation. The following LV parameters were automatically calculated by the software. The 3D strain indexes derived included ,LV peak systolic global longitudinal strain (GLS,percent), LV peak systolic global radial strain (GRS,percent), LV peak systolic global circumferential strain (GCS,percent)

次要结局

  • left ventricular outflow tract gradient before and after Percutaneous Intramyocardial Septal Radiofrequency Ablation(1 year)
  • Interventricular septal thickness before and after Percutaneous Intramyocardial Septal Radiofrequency Ablation(1 year)

研究者

发起方
Xijing Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Liu Liwen

Director

Xijing Hospital

研究点 (1)

Loading locations...

相似试验