跳至主要内容
临床试验/NCT03877211
NCT03877211已完成不适用

Impact of Channel Interaction on Cochlear Implant Performances in Noise : Influence of the Number of Maxima.

Hospices Civils de Lyon2 个研究点 分布在 1 个国家目标入组 28 人开始时间: 2019年2月24日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
28
试验地点
2
主要终点
Percentage of syllable correctly recognized during speech audiometry test

研究概览

简要总结

The goal of this study is to take into account channel interaction in the cochlear implant (CI) fitting process. Designing a fast and accurate method of measurement would help to customize the fitting procedures to patients' specificities in order to maximize speech understanding in every day conditions especially in noise.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Fluent in French
  • •Able to understand written instructions
  • •Under French public medical insurance
  • •Normal-hearing subjects only:
  • •Adult between 18 and 50 years old
  • •Without a remarkable otological medical history, for example: chronic otitis, trans-tympanic tubes and / or all ear surgeries;
  • •Clear auditory canal and normal eardrum;
  • •Average audiometric loss under 20 decibels Hearing Level (dB HL)
  • •Cochlear implant users only:
  • •Adult between 18 and 60 yo
  • •Normal middle ear
  • •Used the cochlear implant for more than a year
  • •Wearing a device from the company Neurelec/Oticon Medical

排除标准

  • •Behavioral and/or neurological disorders
  • •Proven psychological disorder
  • •Use of psychotropic medication
  • •People who experience migraine attacks on a regular basis
  • •Use of ototoxic medication
  • •Exposed to loud noises within the last 72 hours
  • •Included in another clinical trial that uses medication

研究组 & 干预措施

Cochlear implant users

Experimental

Adult cochlear implanted patients wearing an Oticon Medical/Neurelec device will have speech audiometry test in noise, psychophysical tuning curves in forward masking and Electrically-evoked Auditory Brainstem Response (EABR) measurement

干预措施: Psychophysical tuning curves in forward masking (Other)

Cochlear implant users

Experimental

Adult cochlear implanted patients wearing an Oticon Medical/Neurelec device will have speech audiometry test in noise, psychophysical tuning curves in forward masking and Electrically-evoked Auditory Brainstem Response (EABR) measurement

干预措施: Electrically-evoked Auditory Brainstem Response (EABR) (Other)

Cochlear implant users

Experimental

Adult cochlear implanted patients wearing an Oticon Medical/Neurelec device will have speech audiometry test in noise, psychophysical tuning curves in forward masking and Electrically-evoked Auditory Brainstem Response (EABR) measurement

干预措施: speech audiometry in noise (Other)

Normal-hearing subjects

Active Comparator

Normal-hearing subjects will have speech audiometry test in noise, psychophysical tuning curves in forward masking, auditory canal examination and tonal audiometry

干预措施: speech audiometry in noise (Other)

Normal-hearing subjects

Active Comparator

Normal-hearing subjects will have speech audiometry test in noise, psychophysical tuning curves in forward masking, auditory canal examination and tonal audiometry

干预措施: Psychophysical tuning curves in forward masking (Other)

Normal-hearing subjects

Active Comparator

Normal-hearing subjects will have speech audiometry test in noise, psychophysical tuning curves in forward masking, auditory canal examination and tonal audiometry

干预措施: Tonal audiometry (Other)

Normal-hearing subjects

Active Comparator

Normal-hearing subjects will have speech audiometry test in noise, psychophysical tuning curves in forward masking, auditory canal examination and tonal audiometry

干预措施: Auditory canal examination (Other)

结局指标

主要结局

Percentage of syllable correctly recognized during speech audiometry test

时间窗: At inclusion

Subjects will be asked to repeat lists of words played by speakers in a noisy environment generated by the same speakers. A percentage of correct recognition is calculated for each list.

次要结局

  • Sound masking threshold(At inclusion)
  • Electrically-evoked Auditory Brainstem Response (eABR)(Up to 12 months after inclusion)