Evaluation of the Non-invasive Blood Pressure Measured at the Ankle During Cesarean Delivery Compared to the Arm: a Prospective Observational Study

Kasr El Aini Hospital1 个研究点 分布在 1 个国家目标入组 42 人开始时间: 2020年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
42
试验地点
1
主要终点
mean bias and agreement between ankle non-invasive blood pressure and arm non-invasive blood pressure

研究概览

简要总结

Spinal anesthesia-induced maternal hypotension during cesarean delivery is hazardous to the mother and the fetus. Prevention of the unfavorable outcomes of maternal hypotension includes various fluid and vasopressor protocols, and requires careful, frequent monitoring of blood pressure during the first 30 minutes after spinal block. Many clinicians set the blood pressure measurement intervals at 1- minute or 2-minutes intervals during the early period after spinal block. it had been reported that hypotension of duration less than 2 minutes is not harmful to the neonate; thus, the minimum inter-measurement intervals for blood pressure readings should be 2 minutes. This high frequency of blood pressure measurements commonly leads to patient dis-satisfaction due to pain as well as impairment of the interaction with the fetus after delivery. Moreover, the blood pressure measurement in the upper limbs could be affected by movement and shivering.

Using the ankle for measurement of non-invasive blood pressure (NIBP) was previously evaluated in normal subjects, and was reported to be feasible; however, its normal range differed from the arm NIBP. Under spinal anesthesia, the lower limb of the mother is neither mobile, nor sensate. Thus, it was previously hypothesized that measurement of blood pressure at the ankle of the mother could improve patient comfort. Darke and Hill had evaluated the accuracy of non-invasive blood pressure at the arm and the ankle during cesarean delivery. Darke and Hill had reported that the degree of bias between the two sites is not acceptable; however, their study did not evaluate the accuracy of ankle NIBP as a trend monitor to trace the changes in maternal blood pressure. The aim of this work is to evaluate the accuracy and precision of ankle NIBP as a trend monitor in mothers undergoing cesarean delivery under spinal anesthesia.

详细描述

In the preparation room, the parturient will relax in supine position with left uterine displacement by placing a wedge below the right hip. Appropriate size non-invasive blood pressure (NIBP) cuff for the arm and ankle will be chosen according to arm circumference just proximal to antecubital fossa and ankle circumference just above the malleoli, respectively. The cuff's bladder will be directed anteriorly in the arm and in posteriorly in the leg. Simultaneous NIBP measurement of both arms then both ankles will be done. The arm and the ankle with the higher reading will be used for intraoperative NIBP assessment. The baseline reading of the arm and ankle will be obtained as average of 3 reading 2 minutes apart. Simultaneous arm and ankle NIBP measurement will be every 2 minutes from injection of local anesthetic into subarachnoid space till 5 minutes after delivery, then every 5 minutes till the end of surgery. Left uterine displacement will be continued intraoperatively till the delivery. All NIBP measurements will be collected by a research assistant who have no role in parturient management.

Position of the parturient during the spinal anesthesia, drug dosage, fluid management and vasopressor administration will be according to local protocols and the discretion of the attending anesthetist. Intraoperative blood pressure management will be according to the arm NIBP readings

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 35 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • full term singleton pregnant women (18-35 years) scheduled for elective cesarean delivery under spinal anesthesia.

排除标准

  • Patients with coarctation of aorta,
  • cardiac arrythmia,
  • impaired cardiac contractility (ejection fraction< 50%),
  • congenital heart disease,
  • moderate to severe valvular heart disease,
  • uncontrolled hypertension,
  • known peripheral vascular disease,
  • peripartum bleeding,
  • body mass index > 35
  • Condition which preclude placement of blood pressure cuff on either limb (lymphedema, high risk of developing lymphedema, local skin damage, known vascular stenotic lesion, deep venous thrombosis)

结局指标

主要结局

mean bias and agreement between ankle non-invasive blood pressure and arm non-invasive blood pressure

时间窗: intraoperative (every 2 minutes from injection of local anesthetic into subarachnoid space till 5 minutes after delivery, then every 5 minutes till the end of surgery)

mmHg

次要结局

  • The accuracy of ankle systolic blood pressure to diagnose arm absolute systolic hypotension(intraoperative (every 2 minutes from injection of local anesthetic into subarachnoid space till 5 minutes after delivery, then every 5 minutes till the end of surgery))
  • The accuracy of ankle systolic blood pressure to diagnose arm relative systolic hypotension(intraoperative (every 2 minutes from injection of local anesthetic into subarachnoid space till 5 minutes after delivery, then every 5 minutes till the end of surgery))
  • parturient comfort toward arm cuff and ankle cuff(5 minutes after the surgery)
  • arm circumference(5 minutes before the surgery)
  • ankle circumference(5 minutes before the surgery)