Uniformity of Oral Contrast Material in the Bowel
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 900
- 试验地点
- 1
- 主要终点
- Number of Participants With Non-uniform Bowel Lumen Opacification at CT Imaging
研究概览
简要总结
Although positive oral contrast agents are used for the majority of abdominopelvic CT scans in the United States, the quality of bowel opacification has not been compared between the three major classes of positive oral contrast material (barium sulfate, ionic iodinated contrast material, and non-ionic iodinate contrast material). This is a retrospective single institution study of clinical records to show whether the uniformity of bowel opacification is different between the three main types of positive CT oral contrast material used in the United States (Barium sulfate, Diatrizoate, and Iohexol). The investigators will retrospectively identify 250 patients each who received oral barium sulfate, diatrizoate, and iohexol for CT scanning of the abdomen and pelvis (total 750 patients) and assess the quality of bowel lumen opacification by the positive oral contrast agents.
详细描述
Although positive oral contrast agents are used for the majority of abdominopelvic CT scans in the United States, the quality of bowel opacification has not been compared between the three major classes of positive oral contrast material (barium sulfate, ionic iodinated contrast material, and non-ionic iodinate contrast material). The investigators will retrospectively identify 250 patients each who received oral barium sulfate, diatrizoate, and iohexol for CT scanning of the abdomen and pelvis (total 750 patients) and assess the quality of bowel lumen opacification by the positive oral contrast agents.
Primary objective:
- To show the uniformity of bowel opacification is different between the three main types of CT oral contrast material used in the United States (Barium sulfate, Diatrizoate, and Iohexol).
Secondary objectives:
- To show whether or not one of the oral contrast agents provides more uniform opacification than the others in the proximal or distal bowel
- To assess the relative opacification of the distal small bowel (ileum) by the three contrast agents.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •CT scans in which oral contrast material was given
排除标准
- •CT scans in which an obvious paucity of oral contrast material is seen,
- •CT scans of patients who had studies within 1 week prior where enteric contrast may have been given, including fluoroscopic, endoscopic, or interventional studies
研究组 & 干预措施
Barium
Patients who received barium sulfate oral contrast for abdominopelvic CT
干预措施: Barium (Drug)
diatrizoate
Patients who received diatrizoate oral contrast for abdominopelvic CT
干预措施: Diatrizoate (Drug)
iohexol
Patients who received iohexol oral contrast for abdominopelvic CT
干预措施: Iohexol (Drug)
结局指标
主要结局
Number of Participants With Non-uniform Bowel Lumen Opacification at CT Imaging
时间窗: within 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for the imaging appearance of oral contrast uniformity for this outcome.
Nonuniform contrast enhancement of the bowel lumen is a potential diagnostic pitfall at CT imaging since non-uniform enhancement may be distracting to the reader and interfere with accurate diagnosis. Conversely, homogeneously enhancing bowel lumen makes it easier to assess the bowel for potential disease. For each patient's CT scan, the bowel that is seen to be visibly opacified by oral contrast at CT imaging will be assessed as a whole as showing the presence or absence of nonuniform contrast enhancement of the lumen.
Severity of CT Imaging Artifacts Caused by the Oral Contrast Agent
时间窗: within 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for the imaging appearance of oral contrast uniformity for this outcome.
For the segments of bowel visibly opacified by oral contrast, the severity of CT imaging artifacts caused by the oral contrast agent was recorded on the following 3 point scale: 0 = no artifact; 1 = mild artifact without impairment of anatomic delineation; 2 = severe artifact with impairment of anatomic delineation. Lower scores are preferred
次要结局
- Extent of Bowel Opacification of Bowel at CT Imaging(within 1 day from administration of oral contrast. The CT scan generally occurs within 3 hours after oral contrast administration, and the CT scan images will be evaluated for imaging appearance of oral contrast seen in bowel for this outcome.)
研究者
Benjamin M. Yeh, MD
Professor of Radiology. Principal Investigator
University of California, San Francisco