MedPath

Noninvasive Measurement of Sympathetic Nerve Activity in Healthy Volunteers

Not Applicable
Completed
Conditions
Sympathetic Nerve Activity
Interventions
Other: Physiologic maneuvers
Registration Number
NCT02264262
Lead Sponsor
Cedars-Sinai Medical Center
Brief Summary

Activation of the sympathetic nervous system is associated with increased risk of ventricular arrhythmias and sudden cardiac death (SCD). Development of simple, noninvasive, reliable tools to measure sympathetic outflow in human subjects is therefore highly desirable.

Microneurography is the current gold standard measurement technique, whereby multiunit postganglionic sympathetic nerve activity is recorded with tungsten ultrafine microelectrodes inserted selectively into nerve fascicles of the peroneal nerve. Though this technique is considered extremely safe, and has been used successfully for decades in human translational physiology experiments, it has not been adopted for routine clinical assessment due to the requirement for sophisticated equipment and specific technical training and skills. Alternatively, many have adopted heart rate variability as a simple, noninvasive technique for assessing sympathetic nerve activity. However, heart rate variability does not directly measure sympathetic nerve activity, and there is much debate in the literature as to the exact source of sympathetic nerve traffic. For example, many believe it is an accurate reflection of cardiac sympathetic nerve activity, but does not accurately reflect changes in muscle or skin sympathetic nerve activity.

To address these limitations, the investigators have developed a simple, noninvasive technique to measure sympathetic nerve activity using surface electrodes.

Despite its great promise, this new approach has not yet been directly validated. The purpose of this study is therefore to validate this new technique (refered to as EKG-NA) against the current gold standard measurement technique, microneurography.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
4
Inclusion Criteria
  • Age 18-45 years of age
  • BMI < 35 kg/m2
Exclusion Criteria
  • History of hypertension, diabetes, pulmonary disease, metabolic disease or heart failure
  • Cardiac rhythm disorder, specifically: rhythm other than sinus
  • Use of any medications other than common supplements
  • Unable to perform handgrip exercise
  • Pregnant

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Sympathetic nerve activityPhysiologic maneuversHealthy volunteers will undergo microneurography, and non invasive sympathetic nerve activity by EKG analysis at baseline and in response to stress.
Primary Outcome Measures
NameTimeMethod
Chane in Sympathetic nerve activityChange from baseline in sympathetic nerve activity at 2 hours

Multi-unit recordings of sympathetic nerve activity will be obtained with single-use sterile tungsten microelectrodes inserted selectively into muscle or skin nerve fascicles of the peritoneal nerve and EKG-NA by standard surface electrodes

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Cedars-Sinai Medical Center

🇺🇸

Los Angeles, California, United States

© Copyright 2025. All Rights Reserved by MedPath