MedPath

Effect of Different Color Lights on the Internal Clock and Alertness in Humans

Not Applicable
Conditions
Light Flashing
Interventions
Other: Dim light
Other: Flickering light stimuli
Other: Constant light stimuli
Registration Number
NCT05423002
Lead Sponsor
University of Basel
Brief Summary

The main aim of this study is to investigate the effects of cone-modulated light emitted from a visual display on human circadian physiology and cognitive performance in the evening.

Detailed Description

The investigators will generate single/multiple cone-isolating contrasts with equivalent stimuli for other cones and melanopsin photoreceptors. The investigators will assess melatonin suppression under three different light scenarios generated using the method of silent substitution by tuning the spectral composition of the light primaries (e.g. LEDs) such that a single target photoreceptor class is maximally stimulated compared to an equal stimulation of the remaining photoreceptors. Additionally, The investigators will examine pupil response, subjective sleepiness, psychomotor vigilance, visual comfort, and skin temperature under three different light scenarios. This allows for new insights into the lights' cone-contribution mechanism to neuroendocrine physiology in the human retina.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
68
Inclusion Criteria
  • Age: 18 - 35 years
  • Sex: male or female normal color vision, male dichromat (i.e. tested by CCT, HRR, Farnsworth Munsell 100 Hue Test)
  • BMI: 18.5 - 29.9 self-reported weight and height (i.e. normal and overweight according to WHO)
  • Signed consent form of participants
  • Chronotype: Morningness-Eveningness Questionnaire (31 - 69)
  • Sleep Quality: Pittsburgh Sleep Quality Index, PSQI (≤5)
Exclusion Criteria
  • High myopia (> -6 diopters)
  • High hyperopia (< +6 diopters)
  • Transmeridian travel (>2 time zones) <1 month prior to the first session of the study
  • Shift work <3 months prior to the beginning of the study
  • Ophthalmological or optometric conditions (cataract, glaucoma, retinal detachment, macular conditions, chronic inflammations, eye injuries, or operations)
  • General health concerns or disorders, including heart and cardiovascular, neurological, nephrological, endocrinological, and psychiatric conditions
  • Medication impacting on visual, neuroendocrine, sleep, and circadian physiology
  • For females only: pregnancy, use of hormonal contraceptives, lactation or breastfeeding
  • Drug (urinary drug screening) and alcohol use
  • Non-compliance with sleep-wake times: >1 deviation from ±30 minute window sleep and wake-up time
  • Extreme chronotype (Munich Chronotype Questionnaire <2 or >7)
  • Current participation in other clinical trials

Exclusion criteria due to study requirements:

  • Inability to understand and/or follow study materials or procedures
  • Insufficient knowledge of project language

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Arm && Interventions
GroupInterventionDescription
ControlDim lightDim light condition as a baseline
ModulationFlickering light stimuliFlickering light will be added sinusoidally onto the background light.
BackgroundConstant light stimuliConstant light with maximum half irradiance (50%) of all primaries.
Primary Outcome Measures
NameTimeMethod
Melatonin concentration1 year

The saliva samples will be collected from participants every 30 min. The investigators hypothesize that the cone flickering light stimuli will have a different melatonin-attenuating effect than the constant background stimuli and that both will have a different effect than baseline.

Secondary Outcome Measures
NameTimeMethod
Skin temperature1 year

The investigators will monitor skin temperatures using six surface temperature thermocouples (BS 1922L Thermochron iButton®, Maxim, US) placed on proximal and distal regions of the body surface. The investigators hypothesize that the temperature of the body skin will be different in the flickering light stimuli than in the constant stimuli and both will have a different effect in comparison to the baseline.

Subjective sleepiness1 year

The investigators will collect subjective sleepiness ratings using the one-question 9-point Karolinska Sleepiness Scale. The investigators hypothesize that sleepiness (ratings) will be different in the flickering light stimuli than in the constant background light and both will be different than baseline.

Vigilance performance1 year

Sustained attention performance will be assessed throughout the study, using an auditory psychomotor vigilance test (PVT) approach. The investigators hypothesize that the flickering light stimuli will produce different reaction times as measured with the PVT than constant light and baseline. Besides, the baseline will not yield the same reaction times as constant background light.

Pupil response1 year

The investigators will measure changes in the pupil area using a silent substitution Pupillograph. The investigators hypothesize that the pupil constriction will be different after exposure to the light conditions as cones and post-receptoral channels adapt to the light stimuli. Besides, the pupil constriction will change differently under the cone-modulated light when the direction of stimuli is identical to the direction of flickering light condition.

Visual comfort1 year

To assess each participant's subjective perception of visual comfort, The investigators will use a custom 7-point rating scale that probes brightness, light color, and glare perception based on a selection of questions. The investigators hypothesize that visual discomfort ratings will change in the flickering light stimuli in comparison to the constant background stimuli and baseline.

Trial Locations

Locations (1)

Centre for Chronobiology

🇨🇭

Basel, Switzerland

© Copyright 2025. All Rights Reserved by MedPath