跳至主要内容
临床试验/NCT05994092
NCT05994092已完成不适用

Influence of Voluntary Isocapnic Hyperpnea on Blood Lactate Level and Rate of Perceived Exertion

Institute of Sport - National Research Institute, Poland2 个研究点 分布在 1 个国家目标入组 39 人开始时间: 2023年6月10日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
39
试验地点
2
主要终点
Changes in rate of perceived exertion (RPE)

研究概览

简要总结

All the study participants performed the Wingate Anaerobic Test (WAnT) with maximal effort. The experimental group (E) performed a 3-minute recovery protocol based on low-intensity breathing Voluntary Isocapnic Hyperpnea exercises 20 minuter after cessation of the exercise, whereas the control group (C) used passive recovery only. All study participants were advised to sit during the 30-minute period, with minimal walking in order to meet the physiological needs allowed. The blood samples were taken 3 minutes and 30 minutes after cessation of the exercise to measure the bLa. The Borg CR-10 Scale was presented to the participants 3 minutes and 30 minutes after cessation of the exercise to measure the rate of perceived exertion (RPE) (Borg, 1998).

详细描述

All the study participants performed the Wingate Anaerobic Test (WAnT) with maximal effort. The experimental group (E) performed a 3-minute recovery protocol based on low-intensity breathing VIH exercises 20 minuter after cessation of the exercise, whereas the control group (C) used passive recovery only. All study participants were advised to sit during the 30-minute period, with minimal walking in order to meet the physiological needs allowed. The blood samples were taken 3 minutes and 30 minutes after cessation of the exercise to measure the bLa. The Borg CR-10 Scale was presented to the participants 3 minutes and 30 minutes after cessation of the exercise to measure the rate of perceived exertion (RPE).

WAnT was conducted using a Monark 874E Cycle Ergometer (Monark Exercise AB, Sweden). Prior to the test, a standard warm-up of 5 minutes was performed with a load of 0.8-1.2 W/kg. Then, athletes performed a maximal 6-second sprint with a load adjusted to 7.5% of the individual body weight. Following a 2-minute rest period, the athletes underwent a 30-second WAnT with the load adjusted to 7.5% of the individual body weight. The objective for the subjects was to achieve the highest possible peak power as fast as possible and maintain the highest power output throughout the whole test duration. Loud and dynamic verbal encouragement was provided. The testing took place between 9:00 and 10:30 AM. The basic mechanical parameters of the exercise, including performed work and maximum power, were computed with dedicated software (MCE 6.0 - JBA Z. Staniak, Poland) linked to the cycle ergometer.

The recovery protocol consisted of 3' of breathing with 20 breaths·min-1 frequency. The Isocapnic BreathWayBetter devices (Isocapnic Technologies Inc, Kelowna, Canada) with 6-liter bags were used. The protocol was performed in a seating position.

Blood samples were taken from fingertips by skilled technicians to 20 uL capillary tubes. bLa was measured with Super GL2 analyzer (Dr. Müller Gerätebau GmbH, Freital, Germany).

Whereas participants and data collectors were aware of the allocated training method, the laboratory technicians performing biochemistry assays were kept blinded to the allocation. The participants were assigned at random to either E or C group to perform VIH protocol under a supervision of qualified physiotherapist.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

性别
All
接受健康志愿者

入选标准

  • The inclusion criteria:
  • valid medical certificate to compete in speedskating,
  • lack of previous experience with RMT,
  • at least 6 years of athletic training.

排除标准

  • any chronic medical condition,
  • any acute medical condition within last 3 months,
  • any ongoing medication intake.

结局指标

主要结局

Changes in rate of perceived exertion (RPE)

时间窗: 30 minutes

The Borg CR-10 Scale was presented to the participants 3 minutes and 30 minutes after cessation of the exercise to measure the rate of perceived exertion (RPE) (Borg, 1998).

Changes in blood lactate (bLa)

时间窗: 30 minutes

The blood samples were taken 3 minutes and 30 minutes after cessation of the exercise to measure the bLa. Blood samples were taken from fingertips by skilled technicians to 20 uL capillary tubes. bLa was measured with Super GL2 analyzer (Dr. Müller Gerätebau GmbH, Freital, Germany).

次要结局

未报告次要终点

研究者

发起方
Institute of Sport - National Research Institute, Poland
申办方类型
Other
责任方
Principal Investigator
主要研究者

Tomasz Kowalski

Principal Investigator

Institute of Sport - National Research Institute, Poland

研究点 (2)

Loading locations...

相似试验