临床试验/NCT03394768
NCT03394768终止不适用

An Observational Study Comparing NICOM-Cheetah Versus Flotrac-Vigileo for Cardiac Output Monitoring in the Surgical Intensive Care Unit.

Changi General Hospital1 个研究点 分布在 1 个国家目标入组 26 人开始时间: 2018年8月10日最近更新:
适应症

试验速览

阶段
不适用
状态
终止
入组人数
26
试验地点
1
主要终点
Degree of Disagreement, %

研究概览

简要总结

Cardiac output (CO) monitoring is an important tool in critically ill patients with haemodynamic instability. Traditionally, this has been accomplished using the pulmonary artery catheter (PAC). However, its use has been associated with various complications such as pneumothorax, arrhythmia, infection, pulmonary valve injury and embolism. This has led to the development of various minimally invasive cardiac output monitoring devices such as the oesophageal Doppler, PiCCO®, NiCCO® and FloTrac®. These devices however have their inherent limitations and though minimally invasive, are still not without risks to the patient. More recently a completely non-invasive CO monitoring device, NICOM Cheetah® has been introduced. Its use is based on thoracic bioreactance and it involves placement of 4 electrodes on either side of the thorax and it analyses changes in the phase of electrical voltage signal to the current applied across the thorax. Initial validation studies on the NICOM Cheetah® device revealed promising results. This study intends to compare cardiac output monitoring capabilities of the NICOM Cheetah® device using the FloTrac® CO monitor as a reference.

详细描述

This will be a single centre prospective observational study. 50 consecutive patients admitted to the surgical intensive care unit (SICU) who are deemed to require cardiac output monitoring by the treating intensivist will be studied. Data collection is planned to be carried out over 2 consecutive years. Inclusion criteria are: 1) Patients who are deemed to require cardiac output monitoring. 2) Patients 21 years old and above. 3) American Society of Anesthesiologist (ASA) physical status 1 to 4. Exclusion criteria are: 1) Patients who are not on mechanical ventilation. 2) Patients who are not in sinus rhythm. 3) Patients with allergy to adhesive tapes. Patients will be treated as per department protocols and no additional intervention will be performed. Each patient will have an arterial catheter inserted as per our usual practice. All patients will have the FloTrac® connected to the arterial catheter (standard of care in CGH SICU) and the NICOM Cheetah® electrodes placed on the skin across the anterior thoracic wall. The FloTrac CO monitor is the current standard of care for cardiac output monitoring in the SICU of CGH. All patients deemed to require cardiac output monitoring will receive the FloTrac (as per departmental practice). The NICOM CO monitor involves the application of non-invasive sensor strips. In this study, it will be applied to patients receiving the FloTrac (standard of care), on top of the standard care of monitoring with Flotrac. For each patient, standard demographic and SICU data (age, gender, comorbidities, ASA score, admission diagnosis, type of surgery, cause of haemodynamic instability, mean arterial pressure (MAP) and central venous pressure (CVP) at the time of instituting cardiac output (CO) monitoring, use of inotropic support, presence of renal replacement therapy, presence of mechanical ventilation and APACHE II score) will be collected. Cardiac Index (CI) values simultaneously recorded by the NICOM Cheetah® and FloTrac® on a 15-minutely basis for the first 10-hour period will also be collected. These data will be automatically recorded by the FloTrac® Vigilance monitor and the Cheetah NICOM monitor and transcribed to a data entering/analysis software by the principal and co-principal investigators for data analysis.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
21 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients who are deemed to require cardiac output monitoring.
  • Patients 21 years old and above
  • American Society of Anesthesiologist (ASA) physical status 1 to 4

排除标准

  • Patients who are not on mechanical ventilation.
  • Patients who are not in sinus rhythm.
  • Patients with allergy to adhesive tapes

结局指标

主要结局

Degree of Disagreement, %

时间窗: 10 hours of data collected for each participant

Comparison of cardiac output monitoring capabilities of the NICOM Cheetah® versus the FloTrac®. Cardiac output defined as the amount of blood the heart pumps through the circulatory system in a minute. Bland-Altman analysis used to compare the level of disagreement between the 2 devices, %.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Chang See Seong

Consultant

Changi General Hospital