Qualitative Analysis of Photoplethysmography Waveforms for the Detection of Cardiac Arrhythmias Using a Pulse-deriving Smartphone Application
Overview
- Phase
- Not Applicable
- Intervention
- Not specified
- Conditions
- Cardiac Arrhythmia
- Sponsor
- Qompium NV
- Enrollment
- 76
- Locations
- 1
- Primary Endpoint
- Diagnostic accuracy to discriminate between atrial fibrillation and non-atrial fibrillation rhythms
- Status
- Completed
- Last Updated
- 5 years ago
Overview
Brief Summary
Single-lead electrocardiography (ECG) technologies and photoplethysmography (PPG) deriving smartphone apps are gaining interest in the heart rhythm detection space since these apps have the potential to capture and assess heart rhythms. Proprietary arrhythmia detection algorithms are proven to be reliable and accurate. However, insights into the readability of PPG waveforms by human reviewers remain limited. To the investigators' knowledge, there are no publications available regarding the readability of PPG waveforms by human reviewers. The objective of the study was to assess the readability of PPG and single-lead ECG analysis by medical professionals, with respect to the gold-standard 12-lead ECG diagnosis, and investigate whether additional information positively impacts PPG analysis.
Detailed Description
During the study, the readability of PPG and single-lead ECG waveform analysis will be investigated. The objective of the study is to determine the readability of PPG and single-lead ECG measurements, with respect to the gold-standard 12-lead ECG, and investigate whether additional information positively impacts the readability of PPG. Medical professionals (cardiologists and cardiology residents), blinded for the patients' characteristics and history, are instructed to separately analyse the following signals, obtained from 30 patients. * 30 outputs with PPG waveforms * 30 outputs with PPG waveforms with tachogram and Poincaré * 30 outputs with PPG waveforms with tachogram, Poincaré, and algorithm interpretation * 30 outputs with single-lead ECG waveforms * 30 outputs with 12-lead ECG waveforms Participants report the results of the qualitative analysis via a digital questionnaire with multiple-choice questions. Medical professionals classify each rhythm trace as regular rhythm, one or more ectopic/missed heartbeats, atrial flutter, atrial fibrillation, unreadable, or other. The tachogram, Poincaré, and the algorithm interpretation are subsequently added to investigate whether the additional information improves the readability of PPG. Based on the provided answers, the study team will determine the readability of PPG and single-lead ECG analysis interpretation, with respect to the gold-standard 12-lead ECG diagnosis.
Investigators
Eligibility Criteria
Inclusion Criteria
- •Cardiologist or cardiology resident
- •Able to understand Dutch or English
Exclusion Criteria
- Not provided
Outcomes
Primary Outcomes
Diagnostic accuracy to discriminate between atrial fibrillation and non-atrial fibrillation rhythms
Time Frame: Through study completion, an average of 3 months
Readability assessment (sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) of PPG and single-lead ECG signals to detect atrial fibrillation. The readability will be determined and compared with the gold-standard 12-lead ECG diagnosis.
Secondary Outcomes
- Required elements to increase the readability of PPG measurements(Through study completion, an average of 3 months)
- Diagnostic accuracy of PPG analysis: experienced in PPG analysis vs inexperienced in PPG analysis(Through study completion, an average of 3 months)