跳至主要内容
临床试验/NCT04271462
NCT04271462已完成不适用

The Influence of Two Different CO2 Absorbers on Sevoflurane Consumption During Anaesthesia

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)1 个研究点 分布在 1 个国家目标入组 38 人开始时间: 2020年2月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
38
试验地点
1
主要终点
Influence of CO2 filters on Sevoflurane consumption

研究概览

简要总结

Traditional sodalime CO2 absorbers are known to not only react with CO2 but also with sevoflurane. Therewith, a potentially harmful compound (compound A) is formed that can be nephrotoxic. In the United States, the sevoflurane manufacturer therefore recommends keeping the FGF (FGF) at >2.0 L min-1 if a sodalime CO2 absorbent is used. Amsorb Plus® (Datex-Ohmeda Inc., Madison, WI, USA), is a novel type of CO2 absorbent that does not react with sevoflurane. This allows the FGF to be reduced to 0.5 L min-1. This has two important advantages: (i) less fresh sevoflurane is added to the circle system, and (ii) the sevoflurane that is in the system does not react with the CO2 absorber.

Sevoflurane is a potent greenhouse gas with a 100 year CO2-equivalents of 120. Measures that can reduce the consumption of volatile anaesthetics could make a significant contribution to reducing the carbon footprint of the operative process. Additionally, Amsorb Plus® canisters seem to have a longer life span than sodalime canisters and do not need to be disposed of via toxic waste stream, but via domestic waste.

In this study, we were interested if (i) the use of Amsorb Plus leads to a reduction in sevoflurane usage and therefore contribute to a reduction in the CO2 footprint of general anaesthesia with sevoflurane, (ii) Does the use of Amsorb Plus® lead to a reduction in the amount of (toxic) waste produced by operating theatres?

Comparator: a traditional sodalime CO2 absorber (Medisorb™ Multi-Absorber Original, CareFusion, Helsinki, Finland).

研究设计

研究类型
Observational
观察模型
Case Crossover
时间视角
Prospective

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • Unable/ unwilling to participate
  • ASA-IV or higher
  • Age < 18 years
  • Known pregnancy
  • Contra-indications for sevoflurane anaesthesia
  • Emergency surgery
  • Scheduled operating time <2 hours.

结局指标

主要结局

Influence of CO2 filters on Sevoflurane consumption

时间窗: 30 minutes per filter

Comparing Sevoflurane consumption between Amsorb Plus and sodalime CO2 absorbers

次要结局

  • Influence of fresh gas flow on Sevoflurane consumption(30 minutes per fresh gas flow setting)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Niek Sperna Weiland

Staff Anaesthesiologist (MD PhD)

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)

研究点 (1)

Loading locations...

相似试验