MedPath

A Comparison of Ketofol (Ketamine and Propofol Admixture) Versus Propofol as Induction Agents on Hemodynamic Parameters

Not Applicable
Completed
Conditions
Blood Pressure
Interventions
Registration Number
NCT01065350
Lead Sponsor
Mayo Clinic
Brief Summary

This is a pilot study to compare the hemodynamic changes that occur during induction with a novel drug combination known as ketofol (propofol and ketamine admixture with that of propofol alone (prototypic anesthesia induction agent). Propofol and ketamine are widely used as induction agents and their effects on patient hemodynamics are well known. Some of these drug-induced hemodynamic changes are undesirable and lead to deleterious effects on patient hemodynamics. We seek to investigate the hemodynamic changes associated with a novel drug combination known as ketofol (ketamine/propofol admixture) during induction and compare them to propofol. If we determine that the changes produced by ketofol are favorable compared with propofol, we then will seek to test its use in the trauma setting in a subsequent randomized controlled trial.

Detailed Description

This is a pilot study to compare the hemodynamic changes that occur during induction with a novel drug combination known as ketofol with that of propofol. Propofol and ketamine are widely used as induction agents and their effects on patient hemodynamics are well known. Many of these drug-induced changes are undesirable and when used alone sometimes lead to hemodynamic effects on opposite ends of the spectrum, ie. hypotension (propofol) and hypertension (ketamine). We will investigate the hemodynamic changes associated with this drug combination referred to as "ketofol" (ketamine/propofol admixture) during induction compared with propofol as the gold standard induction agent used widely in anesthetic practice. If we validate that the changes produced by the ketofol admixture are favorable, we will then test its use in a wider setting of patient populations including emergency department intubations and the trauma setting.

Background: Propofol is a non-opioid, non-barbiturate, sedative-hypnotic agent with rapid onset and short duration of action. It possesses many favorable effects such as an antiemetic effect and reliably produces sedation and amnesia (Felfernig Jour of Royal Naval Medical Service, '06; White International Anesth Clinics, '88; Willman Ann of Emer Med, '07). However, there are several undesirable side effects such as cardiovascular and respiratory depression. In addition, Propofol as a sole agent has no analgesic properties. These drug-induced side effects have led to alternative drugs being used with the hopes of a more favorable side effect profile. Ketamine is an example of one such drug. Ketamine is a phencyclidine derivative commonly classified as a dissociative sedative with fairly rapid onset and short duration of action (Felfernig Jour of Royal Naval Medical Service, '06; White International Anesth Clinics, '88; Willman Ann of Emer Med, '07). It causes little or no respiratory and cardiovascular depression and unlike propofol, has pain relieving properties. Ketamine as a single induction agent, however, is limited by emergence phenomena including postoperative dreaming and hallucinations, however these are attenuated by the administration of benzodiazepines. Also ketamine in induction doses 1-4.5 mg/kg can have some undesirable effects on hemodynamics (opposite of propofol) in certain patient populations including ischemic heart disease (IHD), and patients with increases in intracranial hypertension and intracranial pressure (ICP). Effectiveness of the two agents in combination has been recently demonstrated and this new combination could allow a novel induction agent with favorable effects on hemodynamics (Felfernig Jour of Royal Naval Medical Service, '06; Hui Jour of Amer Soc of Anesth, '95; Willman Ann of Emer Med, '07). To date, this combination known as ketofol has been used most extensively for procedural sedation in the Emergency Department but has not yet been standardized as an induction agent. We are obtaining funding for a pilot study to validate the use of ketofol as an induction agent.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
85
Inclusion Criteria
  • American Society of Anesthesiologists (ASA) physical status I and II who are to undergo elective general, urologic, orthopedic, plastic, or gynecologic surgery.
Exclusion Criteria
  • patients with age less than 18 yr or over 60 yr,
  • emergency surgery,
  • patients undergoing neurosurgical procedures,
  • any procedure with adjunctive analgesia,
  • any patient on chronic opiate use,
  • females who are known to be pregnant,
  • patients who had ingested psychotropic or sedative medication within one month of investigation,
  • patients with personality disorders,
  • weight greater than 20% of ideal, and
  • any known contraindications to ketamine or propofol.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
PropofolPropofolAs part of the induction, patients will be given 2 milligrams of propofol per kilogram (mg/kg) of body weight. The clinician will receive a 20 milliliter (mL) syringe of propofol. If the dose, 2 mg/kg, does not add up to a total of 20 mL, normal saline will be added to make up for the 20 mL.
KetofolKetamineAs part of the induction, patients will be given 20 mL syringe of an admixture called "ketofol," which combines ketamine and propofol in one syringe. The dose is weight-based such that ketamine will represent 0.75 mg/kg of the dose and propofol, 1.5 mg/kg of the dose.
Primary Outcome Measures
NameTimeMethod
Percent of Subjects With a Greater Than 20% Decrease in Systolic Blood Pressure (SBP) Following Induction of General AnesthesiaBaseline, 5 minutes, 10 minutes, 30 minutes post induction

Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The percentage of subjects experiencing decreases in SBP of greater than 20% during the specified time intervals is reported, as compared to the baseline systolic blood pressure reading. There are two numbers in a blood pressure reading, and they are expressed in millimeters of mercury (mm Hg). This tells how high in millimeters the pressure of your blood raises a column of mercury. The numbers usually are expressed in the form of a fraction; an example of a blood pressure reading is 120/80 mm Hg. The first, or top, number (120 in the example) is the systolic pressure. The systolic pressure is the measure of your blood pressure as the heart contracts and pumps blood.

Secondary Outcome Measures
NameTimeMethod
Percent of Subjects With a Greater Than 20% Decrease in Diastolic Blood Pressure (DBP) Following Induction of General AnesthesiaBaseline, 5 minutes, 10 minutes, 30 minutes post induction

Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The percentage of subjects experiencing decreases in DBP of greater than 20% during the specified time intervals is reported, as compared to the baseline DBP reading. The second or lower number of a blood pressure reading is the DBP and is the measure taken when your heart is at rest.

Percent of Subjects With a Greater Than 20% Decrease in Mean Arterial Pressure (MAP) Following Induction of General AnesthesiaBaseline, 5 minutes, 10 minutes, 30 minutes post induction

MAP was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The percentage of subjects experiencing decreases in MAP of greater than 20% during the specified time intervals is reported, as compared to the baseline MAP reading.

Average Change in Cardiac Output (CO)Baseline, 5 minutes, 10 minutes post induction

CO was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in CO as compared to baseline CO during the specified time intervals is reported.

CO is defined as the quantity of blood ejected per minute by the heart into the systemic circulation. It is the product of the heart rate (HR) (beats per minute) times the stroke volume (SV) (milliliters of blood ejected during each contraction).

Average Change in Cardiac Index (CI)Baseline, 5 minutes, 10 minutes post induction

CI was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in CI as compared to the baseline CI during the specified time intervals is reported.

To determine CI, cardiac output is divided by the body surface area in order to account for body size.

Average Change in Heart Rate (HR)Baseline, 5 minutes, 10 minutes post induction

HR was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in HR (as compared to baseline HR) during the specified time intervals is reported.

Average Change in Systolic Blood Pressure (SBP)Baseline, 5 minutes, 10 minutes post induction

Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in SBP (as compared to baseline SBP) during the specified time intervals is reported.

Average Change in Diastolic Blood Pressure (DBP)Baseline, 5 minutes, 10 minutes post induction

Blood pressure was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in DBP (as compared to baseline DBP) during the specified time intervals is reported.

Average Change in Mean Arterial Pressure (MAP)Baseline, 5 minutes, 10 minutes post induction

MAP was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in MAP from baseline during the specified time intervals is reported.

MAP is a term used in medicine to describe an average blood pressure in an individual. It is defined as the average arterial pressure during a single cardiac cycle.

Average Change in Total Peripheral Resistance (TPR)Baseline, 5 minutes, 10 minutes post induction

TPR was recorded every minute for a total of 30 minutes after anesthesia was induced and readings were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in TPR from baseline during the specified time intervals is reported. TPR is the overall resistance to blood flow through the systemic blood vessels.

Average Change in Total Peripheral Resistance Index (TPRI)Baseline, 5 minutes, 10 minutes post induction

TPRI was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in TPRI from baseline during the specified time intervals is reported.

Average Change in Stroke Volume (SV)Baseline, 5 minutes, 10 minutes post induction

SV was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in SV from baseline during the specified time intervals is reported. SV is the milliliters of blood ejected during each contraction of the heart.

Average Change in Stroke Volume Index (SVI)Baseline, 5 minutes, 10 minutes post induction

SVI was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. The average change in SVI (as compared to baseline SVI) during the specified time intervals is reported. To determine SVI, stroke volume is divided by the body surface area in order to account for body size.

Average Change in Stroke Volume Variation (SVV)Baseline, 5 minutes, 10 minutes post induction

SVV was recorded every minute for a total of 30 minutes after anesthesia was induced and results were captured via a Non-Invasive Cardiac Output Monitor \[NICOM\], Cheetah Medical, Israel. SVV is a dynamic flow-based parameter and together with cardiac output provides an indication of fluid responsiveness. The average change in SVV (as compared to baseline SVV) during the specified time intervals is reported. SVV is calculated by taking the SVmax - SVmin /\*100/ SV mean.

Trial Locations

Locations (1)

Dartmouth Hitchcock Medical Center

🇺🇸

Lebanon, New Hampshire, United States

© Copyright 2025. All Rights Reserved by MedPath