MedPath

Integrating Quantitative MRI and Artificial Intelligence to Improve Prostate Cancer Classification

Recruiting
Conditions
Prostate Carcinoma
Interventions
Procedure: 3 Tesla Magnetic Resonance Imaging
Other: Electronic Health Record Review
Registration Number
NCT04765150
Lead Sponsor
Jonsson Comprehensive Cancer Center
Brief Summary

This study evaluates how new magnetic resonance imaging (MRI) and artificial intelligence techniques improve the image quality and quantitative information for future prostate MRI exams in patients with suspicious of confirmed prostate cancer. The MRI and artificial intelligence techniques developed in this study may improve the accuracy in diagnosing prostate cancer in the future using less invasive techniques than what is currently used.

Detailed Description

PRIMARY OBJECTIVES:

I. To develop and evaluate quantitative dynamic contrast-enhanced (DCE)-MRI analysis techniques that minimize patient- and scanner-specific variabilities in the calculation of quantitative parameters.

II. To develop and evaluate diffusion weighted imaging (DWI) methods that reduce prostate geometric distortion due to patient- and scanner-specific susceptibility and eddy current effects.

III. To develop and evaluate multi-class deep learning models that systematically integrate quantitative multi-parametric (mp)-MRI features for accurate detection and classification of clinically significant prostate cancer (csPCa).

OUTLINE:

RETROSPECTIVE: Patients' medical records are reviewed.

PROSPECTIVE: Patients undergo additional 3 Tesla (T) MRI imaging over 30 minutes before, during, or after their standard of care 3T MRI for a total of 1.5 hours.

Recruitment & Eligibility

Status
RECRUITING
Sex
Male
Target Recruitment
275
Inclusion Criteria
  • Male patients 18 years of age and older
  • Clinical suspicion of prostate cancer or biopsy-confirmed prostate cancer
  • Undergone or undergoing multi-parametric 3 T prostate MRI at the University of California at Los Angeles (UCLA)
  • Ability to provide consent
Exclusion Criteria
  • Contraindications to MRI (e.g., cardiac devices, prosthetic valves, severe claustrophobia)
  • Contraindications to gadolinium contrast-based agents other than the possibility of an allergic reaction to the gadolinium contrast-based agent
  • Prior radiotherapy

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Observational (electronic health record review, 3 T MRI)3 Tesla Magnetic Resonance ImagingRETROSPECTIVE: Patients' medical records are reviewed. PROSPECTIVE: Patients undergo additional 3T MRI imaging over 30 minutes before, during, or after their standard of care 3T MRI for a total of 1.5 hours.
Observational (electronic health record review, 3 T MRI)Electronic Health Record ReviewRETROSPECTIVE: Patients' medical records are reviewed. PROSPECTIVE: Patients undergo additional 3T MRI imaging over 30 minutes before, during, or after their standard of care 3T MRI for a total of 1.5 hours.
Primary Outcome Measures
NameTimeMethod
Development of diffusion weighted imaging (DWI) methods that reduce prostate geometric distortionUp to 5 years

Differences between rectangular field of view-ENCODE and standard DWI in terms of the prostate Dice's similarity coefficient (primary outcome) and apparent diffusion coefficient consistency will be compared.

Development of quantitative dynamic contrast (DCE)-enhanced-magnetic resonance imaging (MRI) analysis techniquesUp to 5 years

Both transfer constant (Ktrans) and rate constant (Kep) from normal prostate tissue will be evaluated for the inter-scanner variability. Pairwise dissimilarities between distributions will be estimated by computing the Kolmogorov-Smirnov statistic, defined as the maximum difference between the empirical distribution functions over the range of the parameter, using 200 cases for each of three MRI scanners. The mean of these pairwise dissimilarities between scanners will be computed to quantify the overall discrepancy of each DCE-MRI model. Construction of a 95% confidence interval for the difference in the mean discrepancies using the nonparametric bootstrap will be done to compare this mean discrepancy between DCE-MRI models. 10,000 bootstrap samples will be generated by sampling patients with replacement, stratifying by the scanner. Will conclude that the proposed DCE-MRI model has a reduced inter-scanner variability if the 95% confidence interval is entirely less than zero.

Development of multi-class deep learning modelsUp to 5 years

The overall performance of FocalNet and Prostate Imaging Reporting \& Data System version 2 will be compared in terms of area under the curve. Comparison between area under the curves will be performed using DeLong's test. Will also include the comparison between FocalNet and baseline deep learning methods (U-Net and Deeplab without focal loss \[FL\] and mutual finding loss \[MFL\]) to characterize the advantages of using FL and MFL with the same study cohort. For each of these approaches, an optimal cut-point for classification of clinically significant prostate cancer will be identified by maximizing Youden's J (= sensitivity + specificity - 1) and will report sensitivity, specificity and 95% confidence intervals based on the selected cut-point.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

UCLA / Jonsson Comprehensive Cancer Center

🇺🇸

Los Angeles, California, United States

© Copyright 2025. All Rights Reserved by MedPath