ANALYSIS OF DEPOSITION RADIOAEROSOL NEBULIZERS MEMBRANE IN HEALTHY SUBJECTS
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 15
- 试验地点
- 2
- 主要终点
- radioaerosol deposition index into the lungs
研究概览
简要总结
BACKGROUND: Mesh nebulizers (MN) have lower residual volume and increased inhaled dose compared to jet nebulizers (JN) per in vitro and animal models. The aim of this study was to compare radioaerosol deposition using MN and JN in healthy subjects, using 2-D planar scintigraphy. METHODS: A randomized trial in 6 normal subjects (4 female, 2 male) inhaled 99mTc-DTPA with an activity of 1 mCi with the normal saline to a total dose of 4 mL with JN (Misty Max, Air Life, Yorba Linda, USA) oxygen flow of 8 L / min and 1.5 mL with MN (Aeroneb Solo with Ultra adapter; Aerogen Galway, Ireland). Scintigraphy was used to determine distribution of deposition and mass balance between compartments.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •The study inclusion critera was healthy adults of both sexes, between 18 to 65 years, without history of lung disease or smoking, with forced vital capacity (FVC) or forced expiratory volume in the first second (FEV1) greater or equal to 80% of predicted values (Pereira et al., 1992), ability to follow and retain verbal commands while able and willing to provide signed consent to participate in this study.
排除标准
- •Participants were excluded if they have been diagnosed with a lung disease, current smoker, unable to understand and follow the procedures and pregnant or unable to tolerate nebulization.
结局指标
主要结局
radioaerosol deposition index into the lungs
时间窗: 1 month
Immediately after inhalation, participants sat in a chair with the back positioned in front to the gamma camera (STARCAM 3200 GE, California, USA) to obtain radioactivity counts from the posterior thorax during a period of 300 seconds on a matrix of 256 X 256. After, participants were positioned sitting in front to the gama camera to obtain images from face. Then, the same procedure was performed to analysis deposition in the nebulizer, circuits, inspiratory filter, expiratory filter and face mask. Counts representing stomach were obtained from posterior thorax and corrections for decay of technetium were used to during extrapulmonary measurements
次要结局
未报告次要终点
研究者
Daniella Cunha Brandao
Daniella Cunha Brandão
Universidade Federal de Pernambuco