跳至主要内容
临床试验/NCT02501655
NCT02501655Unknown不适用

ANALYSIS OF DEPOSITION RADIOAEROSOL NEBULIZERS MEMBRANE IN HEALTHY SUBJECTS

Daniella Cunha Brandao2 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2015年7月最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
15
试验地点
2
主要终点
radioaerosol deposition index into the lungs

研究概览

简要总结

BACKGROUND: Mesh nebulizers (MN) have lower residual volume and increased inhaled dose compared to jet nebulizers (JN) per in vitro and animal models. The aim of this study was to compare radioaerosol deposition using MN and JN in healthy subjects, using 2-D planar scintigraphy. METHODS: A randomized trial in 6 normal subjects (4 female, 2 male) inhaled 99mTc-DTPA with an activity of 1 mCi with the normal saline to a total dose of 4 mL with JN (Misty Max, Air Life, Yorba Linda, USA) oxygen flow of 8 L / min and 1.5 mL with MN (Aeroneb Solo with Ultra adapter; Aerogen Galway, Ireland). Scintigraphy was used to determine distribution of deposition and mass balance between compartments.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • The study inclusion critera was healthy adults of both sexes, between 18 to 65 years, without history of lung disease or smoking, with forced vital capacity (FVC) or forced expiratory volume in the first second (FEV1) greater or equal to 80% of predicted values (Pereira et al., 1992), ability to follow and retain verbal commands while able and willing to provide signed consent to participate in this study.

排除标准

  • Participants were excluded if they have been diagnosed with a lung disease, current smoker, unable to understand and follow the procedures and pregnant or unable to tolerate nebulization.

结局指标

主要结局

radioaerosol deposition index into the lungs

时间窗: 1 month

Immediately after inhalation, participants sat in a chair with the back positioned in front to the gamma camera (STARCAM 3200 GE, California, USA) to obtain radioactivity counts from the posterior thorax during a period of 300 seconds on a matrix of 256 X 256. After, participants were positioned sitting in front to the gama camera to obtain images from face. Then, the same procedure was performed to analysis deposition in the nebulizer, circuits, inspiratory filter, expiratory filter and face mask. Counts representing stomach were obtained from posterior thorax and corrections for decay of technetium were used to during extrapulmonary measurements

次要结局

未报告次要终点

研究者

发起方
Daniella Cunha Brandao
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Daniella Cunha Brandao

Daniella Cunha Brandão

Universidade Federal de Pernambuco

研究点 (2)

Loading locations...

相似试验