MedPath

A Comparison of Optimal PEEP Determination Guided by EIT and G5 Device in Moderate and Severe ARDS Patients

Not Applicable
Completed
Conditions
Acute Respiratory Distress Syndrome
Interventions
Device: optimal PEEP guided by G5 ventilator
Device: optimal PEEP guided by EIT
Registration Number
NCT03112512
Lead Sponsor
Mei-Yun Chang
Brief Summary

To Select the Optimal Positive End-expiratory Pressure in Moderate and Severe Acute Respiratory Distress Syndrome Patients by Using:

1. the novel Non-invasive Electrical Impedance Tomography Guided Method

2. the Protective ventilation tool G5(MV)

Detailed Description

1. To titrate PEEP guided by EIT. A global inhomogeneity (GI) index and regional compliance based on EIT were developed to quantify the tidal volume distribution within the lung. The aim of this study was to test the feasibility of optimizing PEEP with respect to ventilation homogeneity using the GI index and regional compliance.

2. To titrate PEEP with the Protective Ventilation Tool by G5(MV). The new generation of ventilator will deliver an optimal PEEP on ARDS patients based on their status automatically.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
88
Inclusion Criteria
  1. ARDS patients
  2. Transferred from FEMH emergency room or Ward into the medical intensive care unit.
  3. Patients with invasive mechanical ventilation
  4. Patient, agent or consent of families learn about and subjects were willing to sign the consent form.
Exclusion Criteria
  1. burning electric knife used
  2. pacemaker used
  3. Large area wound is used gauze to cover
  4. Wound or burn injuries of the chest wall.
  5. Patients included conditions are not met.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
G5 VENTILATORoptimal PEEP guided by G5 ventilatorProtective Ventilation Tool by G5(MV) to determine the optimal PEEP on ARDS patients. The results are delivered by the ventilator automatically.
EIToptimal PEEP guided by EITPEEP titration is performed where EIT is measured at the same time. After PEEP titration, EIT data is analyzed. Global inhomogeneity index and regional compliance based on EIT are calculated. PEEP level is selected when ventilation distribution is most homogeneous.
Primary Outcome Measures
NameTimeMethod
Respiratory system parameter48 hrs

Compliance

Secondary Outcome Measures
NameTimeMethod
Respiratory system parameter48 hrs

PaO2/FiO2

MV day64 days

Number of days with ventilator and ICU stay

Trial Locations

Locations (1)

Electrical impedance tomography (EIT)

🇨🇳

New Taipei City, No.21, Sec. 2, Nanya S. Rd., Banciao Dist, Taiwan

© Copyright 2025. All Rights Reserved by MedPath