Double Lumen Tube Positioning With Bonfils Fiberoptic Stylet: Prospective Observational Study in 30 Adult Patients
- Conditions
- Difficult IntubationThoracic Surgery
- Registration Number
- NCT03982745
- Lead Sponsor
- Università Politecnica delle Marche
- Brief Summary
The aim of this prospective observational study is to evaluate the efficacy of Bonfils fiberoptic stylet to perform tracheal intubation with double lumen tube after failure of standard laryngoscopy in 30 adults patients scheduled for elective thoracic surgery, who require tracheal intubation with double lumen tube for One Lung Ventilation under general anesthesia in a teaching hospital operating theatre at Ospedali Riuniti Ancona (Italy).
- Detailed Description
This is a prospective, observational study, approved by Marche's Regional Ethics Committee (CERM), Ancona, ITA on the 07 February 2019. The study is conformed to the Declaration of Helsinki and Good Clinical Practice guidelines, an informed written consent will be obtained at recruitment.
The aim of this study is to evaluate the efficacy of Bonfils fiberoptic stylet to perform tracheal intubation with double lumen tube (DLT) after failure of standard laryngoscopy in 30 adult patients (patients 18 years of age) scheduled for elective thoracic surgery, who require tracheal intubation with (DLT) for One Lung Ventilation (OLV) under general anesthesia. The study will be performed in a teaching hospital operating theatre at AOU Ospedali Riuniti Ancona (Italy).
Pre-operative evaluation will be done before surgery, demographic variables will be collected and the clinical screening tests to predict a difficult airway will be performed.
On the day of the intervention, patients will be subjected to standard monitoring of vital signs (NIBP, FC, SpO2 and ECG) and, after induction of general anesthesia and adequate pre-oxygenation (3-minutes with facial mask ventilation), a direct laryngoscopy with Macintosh blade will be performed to insert a DLT. The Cormack-Lehane grade view will be registered after optimization of the intubation attempt by improving the "sniffing position" and the external manipulation of the larynx (BURP maneuver). In case of declaration of intubation failure, it will be used Bonfils fiberscope for the DLT insertion.
A maximum duration of intubation attempt is not established, but a decrease in SpO2 below 90% will be considered as a criterion for abandoning the procedure and the patient will be re-oxygenated.
The maximum number of attempts allowed will be 2 for the Macintosh laryngoscope and 2 for the Bonfils fiberscope, after which, in case of failure with the both devices, the patient will be awakened.
In any case of difficulty in patient oxygenation and ventilation with facial mask, a second generation laryngeal mask will be used. The following parameters relating to the patients recruited in the study will be recorded: weight, height, BMI, Mallampati score, interincisor distance, chin-Thyroid distance, Cormack-Lehane view grade at direct laryngoscopy.
The primary end point of this study is to assess the success rate of DLT insertion with Bonfils fiberscope.
The duration of the procedure, the number of attempts and the occurrence of any complications will also be recorded
Data analysis will be performed using the Medcalc 7.3.0.1 statistical program (Medcalc software, Ostend, Belgium). Kolmogorov-Smirnov's test will be used to test the normality of distribution.
Data will be presented as mean ± dev. standard or median and 95% confidence interval.
The results will be averaged, and the data will be presented as mean SD for each variable with continuous data. Values of P less than 0.05 will be considered as statistically significant.
The differences between means will be studied by parametric tests (eg Student's t) if the data are normal distribution and non-parametric tests (eg Wilcoxon) if the distribution is not normal.
With regard to the efficacy of Bonfils fiberscope, literature have been reported a success rate higher than 80%. Therefore, assuming a success rate of around 90% (and accepting a standard deviation of 10%), we should study at least 30 patients for whom we expect to have a correct tracheal intubation on about 27 patients. A 5% SD would mean that intubation will be successful in at least 26 patients (85%), which we believe could be considered an excellent result.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 30
- adults (age≥18 years)
- tracheal intubation with double lumen tube (DLT) for One Lung Ventilation (OLV) required for elective thoracic surgery under general anaesthesia
- patients undergoing emergency thoracic surgery
- patients with predictive criteria of difficult ventilation scheduled for "awake endoscopic intubation"
- patients with anatomical features that contraindicate direct laryngoscopy
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method the efficacy of Bonfils fiberoptic stylet to perform tracheal intubation with double lumen tube after failure of standard laryngoscopy up to 2 minutes from device insertion the success rate of the procedure defined by the correct position of the double-lumen tube in the bronchial lumen verified by a flexible fiberscope
- Secondary Outcome Measures
Name Time Method Time to intubation, up to 2 minutes from device insertion Time in minutes measured from device insertion into the patient's mouth until the DLT will be positioned into the bronchial lumen.
Any complications occurred up to 12 hours measured from the insertion of the device number of patients that axperienced desaturation, hemodynamic alterations, oral cavity-pharynx and larynx traumatism
Number of intubation attempts up to 15 minutes. The maximum number of attempts allowed will be 2 for the Macintosh laryngoscope and 2 for the Bonfils fiberscope, after which, in case of failure with the both devices, the patient will be awakened. number of attempt to intubation. intubation will be considered complete when the DLT will be positioned correctly into the bronchial lumen.
Trial Locations
- Locations (1)
AOU Ospedali Riuniti Ancona - Università Politecnica delle Marche
🇮🇹Ancona, Italy