MedPath

McGRATH vs Macintosh Laryngoscopy Comparison in LMA Insertion

Not Applicable
Completed
Conditions
Anesthesia
Intubation Complication
Intubation;Difficult
Interventions
Device: McGRATH laryngoscopy
Device: Macintosh laryngoscopy
Registration Number
NCT04509453
Lead Sponsor
Udayana University
Brief Summary

Various techniques have been developed to get a good LMA position, one of them is using a laryngoscope. The most popular laryngoscope used for LMA installation is the Macintosh type. Technological developments have brought laryngoscopes into the video era, one of which is McGRATH's laryngoscope, which from several studies about having an advantage in terms of the first attempt, time, complications, and hemodynamic stability of intubation. It needs to be proven through research on the comparison of clinical outcomes of LMA installation with McGrath laryngoscope and Macintosh laryngoscope.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
102
Inclusion Criteria
  • Patients underwent surgery with general anesthesia by LMA insertion in Sanglah General Hospital
  • Agreed to be included in the study by signing informed consent
  • American Society of Anesthesiologist physical status 1-2
Exclusion Criteria
  • Patients unfit for LMA insertion
  • Patients with suspected airway management difficulty
  • Pregnancy
  • Morbid obese

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
MacintoshMacintosh laryngoscopy-
McGRATHMacintosh laryngoscopy-
MacintoshMcGRATH laryngoscopy-
McGRATHMcGRATH laryngoscopy-
Primary Outcome Measures
NameTimeMethod
Number of participants with first-attempt successimmediately after LMA insertion

Successful LMA insertion within first attempt

Heart rateimmediately after LMA insertion

Heart rate measured by standard monitor

Mean arterial pressureimmediately after LMA insertion

Mean arterial pressure measured by non-invasive blood pressure monitor

Secondary Outcome Measures
NameTimeMethod
ComplicationsAn hour after the the end of surgery

Incidence of hoarseness or throat pain due to LMA insertion

Time requiredimmediately after LMA insertion

Time required for LMA insertion using the respective method

Trial Locations

Locations (1)

Sanglah General Hospital

🇮🇩

Denpasar, Bali, Indonesia

© Copyright 2025. All Rights Reserved by MedPath