跳至主要内容
临床试验/NCT03296319
NCT03296319已完成不适用

Echocardiography Guided Fluid Resuscitation in Critically Ill Patients

Assiut University2 个研究点 分布在 1 个国家目标入组 120 人开始时间: 2018年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
120
试验地点
2
主要终点
The impact of echocardiography guided fluid resuscitation

研究概览

简要总结

To compare between the impact of echocardiography guided fluid resuscitation and clinically guided fluid resuscitation on critically ill patients in hospital outcome.

详细描述

Resuscitation often requires the infusion of intravenous fluid in an effort to reverse organ dysfunction. The harms of inappropriate use of fluid are becoming increasingly apparent The question of whether the patient improves with fluid, additional vasopressors or inotropes can be difficult to answer. The gold standard for assessing fluid responsiveness to guide fluid administration in critically ill patients is to perform a fluid challenge. The rationale for volume expansion is to increase the cardiac output (CO) and oxygen delivery to ultimately improve tissue oxygenation. This involves the infusion of a specific amount of intravenous fluid to assess ventricular preload reserve and subsequent systemic haemodynamic effects. In a patient with acute hemodynamic instability, a fluid challenge will cause an increase in stroke volume, according to the Frank-Starling curve. This increase in stroke volume has a salutary effect because it improves tissue perfusion. In contrast, higher hydrostatic pressures in the vascular system predispose the patient to edema, organic dysfunction, and increased risk of in-hospital mortality.

Fluid responsiveness is conventionally defined as an increase of at least 10% to 15% in SV in response to a fluid challenge, which is a reflection of the limits of precision of the technology used.

Assessment of the response in flow to a fluid challenge can be guided with echocardiography. It is achieved by measuring left ventricular outflow tract velocity time integral (LVOT VTI) immediately before and after fluid challenge.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Investigator)

入排标准

性别
All
接受健康志愿者

入选标准

  • 1- All Critical ill-patients with Acute Physiologic Assessment and Chronic Health Evaluation II score (APACHE II score)≥ 25

排除标准

  • Bad echocardiographic window
  • APACHE II score < 25.

结局指标

主要结局

The impact of echocardiography guided fluid resuscitation

时间窗: Baseline

we will compare the results of fluid administration between two groups of patients with APACHE II score \> 25: the first group using clinical sense only and the other group using transthoracic echocardiography including: The sample box of PW Doppler will be placed at thelevel of the aortic valve or within 1 cm of it, in the LVOT. Peak velocity variation of 12% before and after 250 cc normal saline challenge in adults predicts fluid responsiveness (12) and VTI variation is also predictive. The percentage variations in SV, VTI or peak velocity are calculated using the following equation: variations =100 x svmax-svmin/(svmax+svmin) x 0.5.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Mohammed Esam

Assistant Lecturer

Assiut University

研究点 (2)

Loading locations...