Simplified Assessment of Left Ventricular Systolic Function in Septic Shock Patients

Centre Hospitalier Universitaire, Amiens2 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2021年9月20日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
80
试验地点
2
主要终点
Concordance between GLS and echocardiographic algorithm

研究概览

简要总结

The assessment of left ventricular systolic function is based on the measurement of left ventricular ejection function (LVEF) by the Simpson biplane method. More recently, left ventricular global longitudinal strain (GLS) has been developed to detect abnormalities of cardiac contractility in patients with preserved myocardial contractility. However, both tools are not always easy to collect in practice. This is why other ultrasound parameters have been proposed in the literature as a substitute for LVEF and GLS such as the Doppler tissue imaging (DTI)-derived mitral annular systolic peak S-wave velocity (S'), the mitral annular plane systolic excursion (MAPSE) and the longitudinal wall fractional shortening index (LWFS).

The purpose of this project is to propose an algorithm using simple parameters (S' wave, lateral MAPSE, septal MAPSE, mean MAPSE and LWFS) to predict LVEF and GLS in order to diagnose patients with impaired systolic function and preserved ejection.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients hospitalized in the Medical Intensive Care Department of the Amiens-Picardie University Hospital for the management of septic shock.
  • Septic shock is defined by sepsis with a need for vasopressor amines to maintain a mean arterial pressure higher than or equal to 65 mmHg, and associated with hyperlactatemia (higher than 2 mmol/L).
  • A transthoracic echocardiography should be performed within 72 hours of the diagnosis of septic shock.

排除标准

  • Patient with cardiac arrhythmias,
  • patients with severe mitral or aortic valve disease,
  • patients with fused mitral Doppler flow,
  • patients with insufficient echogenicity to allow a correct assessment of left ventricular systolic function.

结局指标

主要结局

Concordance between GLS and echocardiographic algorithm

时间窗: 3 months

left ventricular global longitudinal strain = GLS The echocardiographic parameters used are: lateral S' wave; septal, lateral and mean MAPSE; and LWFS.

Concordance between LVEF and echocardiographic algorithm

时间窗: 3 months

left ventricular ejection function = LVEF The echocardiographic parameters used are: lateral S' wave; septal, lateral and mean MAPSE; and LWFS.

次要结局