Investigation of Dynamic Hyperinflation and Its Relationship With Functional Exercise Capacity in Children With Bronchiectasis
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- Dynamic hyperinflation
研究概览
简要总结
Prevalence of dynamic hyperinflation and its relationship with functional exercise capacity will be evaluated in children with bronchiectasis.
详细描述
Exercise or hyperpnea-induced air trapping is referred to as dynamic hyperinflation. In the presence of high resistance to expiratory flows and short expiratory times, the respiratory system is unable to return to its resting volume at the end of exhalation. The positive pressure within regions of hyperinflated lung raises the mean intrathoracic pressure and causes the inspiratory muscles to operate at a higher than resting lung volume. Thus, dynamic hyperinflation places the respiratory muscles at a considerable mechanical disadvantage and further impairs respiratory function. Dynamic hyperinflation is considered to be a key determinant of exercise capacity in patients with obstructive lung diseases. Although bronchiectasis is one of the obstructive lung diseases, the presence of dynamic hyperinflation in these patients has not been adequately investigated. Management guidelines of bronchiectasis state that imaging methods or pulmonary function tests alone is not sufficient to determine the disease burden and prognosis in these patients, so they recommend including detailed evaluation of exercise tolerance in the management of bronchiectasis. Aim of this study is to investigate the prevalence of dynamic hyperinflation and its relationship with functional exercise capacity in children with bronchiectasis.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Prospective
入排标准
- 年龄范围
- 8 Years 至 18 Years(Child, Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Diagnosis of bronchiectasis
排除标准
- •Hospitalization history during past month
- •Diagnosis of any other chronic childhood diseases such as cerebral palsy or neuromuscular diseases which may impede exercise tolerance
结局指标
主要结局
Dynamic hyperinflation
时间窗: At baseline
Dynamic hyperinflation will be defined as a decrease of \>100 mL in inspiratory capacity at the end of six-minute walk test determined by Spiropalm 6MWT device.
次要结局
- Peak Expiratory Flow (PEF)(At baseline)
- Six-minute walk distance(At baseline)
- Breathing reserve(At baseline)
- M. Quadriceps strength(At baseline)
- Leicester Cough Questionnaire(At baseline)
- Handgrip strength(At baseline)
- Forced Expiratory Volume in 1 second (FEV1)(At baseline)
- Minute ventilation(At baseline)
- Forced Vital Capacity (FVC)(At baseline)
研究者
Melih Zeren
Assist. Prof. Dr.
Izmir Bakircay University