MedPath

DEF-314 Better Accuracy in Ejection Fraction (EF) Assessment With DEFINITY

Phase 3
Completed
Conditions
Cardiac Disease
Interventions
Registration Number
NCT03571672
Lead Sponsor
Lantheus Medical Imaging
Brief Summary

This is a Phase 3, prospective, open-label, multicenter study to evaluate Left Ventricular Ejection Fraction (LVEF) measurement accuracy and reproducibility of DEFINITY® contrast-enhanced and unenhanced echocardiography as compared with non-contrast cardiac magnetic resonance imaging (CMR) used as the truth standard.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
153
Inclusion Criteria
  1. Men and women ≥ 18 years of age in sinus rhythm
  2. Able to communicate effectively with trial personnel
  3. Has undergone a 2D Echo with or without contrast obtained within 6 months prior to enrollment (Day 0)
  4. Has provided signed informed consent after receiving a verbal and written explanation of this clinical trial -
Read More
Exclusion Criteria
  1. Female subjects who are pregnant or lactating. All women of child bearing potential [WOCBP] must have a negative urine pregnancy test at screening regardless of contraceptive use history.

  2. Women of child-bearing potential are excluded unless they:

    1. are post-menopausal defined as amenorrhea ≥ 12 consecutive months, OR
    2. have undergone successful surgical sterilization (hysterectomy, bilateral tubal ligation or bilateral oophorectomy), OR
    3. have been using an adequate and medically approved method of contraception to avoid pregnancy for at least 1 month prior to DEFINITY® dose administration and be willing to continue using the same method for the duration of the study.
  3. Current illness or pathology that would prevent undergoing investigational product administration due to a significant safety risk to the patient.

  4. Uncontrolled arterial hypertension (defined as systolic blood pressure ≥ 200 mmHg or diastolic blood pressure ≥ 110 mmHg) or arterial hypotension (defined as systolic blood pressure ≤ 90 mmHg).

  5. Unstable cardiovascular status defined as:

    1. myocardial infarction or unstable angina pectoris within 6 months prior to enrollment/DEFINITY® dose administration day
    2. transient ischemic attack or stroke within 3 months prior to DEFINITY® dose administration
    3. symptomatic valvular heart disease or moderate to severe stenotic valvular heart disease
    4. clinically significant congenital heart defects
    5. current uncontrolled cardiac arrhythmias causing symptoms or hemodynamic compromise
    6. acute pulmonary embolus or pulmonary infarction
    7. acute myocarditis or pericarditis
    8. acute aortic dissection
    9. atrial fibrillation
  6. any major surgery within 4 weeks prior to screening

  7. known contraindications to undergoing CMR or claustrophobia

  8. participation in any investigational drug, device, or placebo study within 30 days prior to screening

  9. known hypersensitivity to perflutren, or any of the excipients in DEFINITY®

  10. prisoners or those who are subject to compulsory detention or involuntary incarceration for treatment of either a psychiatric or physical illness (e.g., infectious disease) -

Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
DEFINITYDEFINITYEach patient will undergo an unenhanced ultrasound examination and a DEFINITY contrast-enhanced ultrasound
Primary Outcome Measures
NameTimeMethod
Absolute Value of LVEF Percentage Differences From CMR by Blinded ReaderUp to 30 days between day of echocardiograms and CMR imaging

Demonstrate improvement in accuracy in left ventricular ejection fraction (LVEF) assessment using Definity contrast-enhanced over unenhanced echocardiography by comparing LVEF Percentage Differences from CMR measured by 3 independent blinded image readers.

Secondary Outcome Measures
NameTimeMethod
Secondary Objective 1: Absolute Value of LVEF Percentage Differences From CMR by Blinded Reader for Suboptimal EchocardiogramsUp to 30 days between day of echocardiograms and CMR imaging

Demonstrate improvement in accuracy in left ventricular ejection fraction (LVEF) assessment using DEFINITY® contrast-enhanced over unenhanced echocardiography in subjects with suboptimal echocardiograms by comparing LVEF percentage differences from CMR measured by 3 independent readers.

Secondary Objective 3: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded ReadersUp to 30 days between day of echocardiograms and CMR imaging

Demonstrate a reduction in inter-reader variability for the assessment of end-diastolic and systolic volumes using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing end-diastolic and systolic volume differences from CMR between 3 independent blinded readers.

Secondary Objective 4: Absolute Value of LVEF Percentage Differences From CMR Between Blinded Readers for Suboptimal EchocardiogramsUp to 30 days between day of echocardiograms and CMR imaging

Demonstrate a reduction in inter-reader variability for the assessment of left ventricular ejection fraction using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing LVEF Percentage Differences from CMR between 3 independent blinded readers in subjects with suboptimal echocardiograms.

Secondary Objective 5: Absolute Value End-Diastolic and Systolic Volume Differences From CMR Between Blinded Readers for Suboptimal EchocardiogramsUp to 30 days between day of echocardiograms and CMR imaging

Demonstrate a reduction in inter-reader variability for the assessment of end-diastolic/systolic volumes using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing end-diastolic and systolic volume differences from CMR between 3 independent blinded readers in subjects with suboptimal echocardiograms.

Secondary Objective 2: Absolute Value LVEF Percentage Differences From CMR Between Blinded ReadersUp to 30 days between day of echocardiograms and CMR imaging

Demonstrate a reduction in inter-reader variability for the assessment of left ventricular ejection fraction using DEFINITY® contrast-enhanced versus unenhanced echocardiography by comparing LVEF Percentage Differences from CMR between 3 independent blinded readers

Trial Locations

Locations (9)

Alfieri Cardiology

🇺🇸

Wilmington, Delaware, United States

Banner University of Arizona Medical Center

🇺🇸

Tucson, Arizona, United States

Weill Cornell Medical Center

🇺🇸

New York, New York, United States

University of California-San Diego

🇺🇸

San Diego, California, United States

Henry Ford Hospital

🇺🇸

Detroit, Michigan, United States

Duke University

🇺🇸

Durham, North Carolina, United States

University Hospital/Cleveland Medical Center

🇺🇸

Cleveland, Ohio, United States

West Virginia University Medical Center

🇺🇸

Morgantown, West Virginia, United States

Thomas Jefferson University

🇺🇸

Philadelphia, Pennsylvania, United States

© Copyright 2025. All Rights Reserved by MedPath