Comparison of Different Inspiratory to Expiratory Ratios on Respiratory Mechanics and Oxygenation in Robot-assisted Laparoscopic Radical Prostatectomy With Steep Trendelenburg Position and Pneumoperitoneum
- Conditions
- General Anesthesia Using Endotracheal Intubation
- Registration Number
- NCT01892449
- Lead Sponsor
- Yonsei University
- Brief Summary
The steep trendelenburg position and pneumoperitoneum during laparoscopic surgery have the potential to cause an adverse effects on respiratory mechanics and gas exchange. Previous studies have proposed that a prolonged I:E ratio ventilation improved respiratory mechanics and gas exchange. Therefore, the aim of this study is to evaluate whether a prolonged I:E ratio ventilation improves gas exchange and respiratory mechanics in patients undergoing robot-assisted laparoscopic radical prostatectomy.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Male
- Target Recruitment
- 80
- Adult male patients (20-90 years of age) scheduled for elective robot-assisted laparoscopic radical prostatectomy undergoing general anesthesia
- Patients with an abnormal airway anatomy, reactive airway diseases, chronic respiratory diseases, a history of coronary artery diseases, or heart failure
- BMI > 30 kg/m 2
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Primary Outcome Measures
Name Time Method The peak inspiratory pressure before 10 minutes after anesthesia induction, 30 and 60 minutes after steep trendelenburg position and pneumoperitoneum, and 10 minutes after supine position and CO2 desufflation The peak inspiratory pressure during mechanical ventilation with endotracheal intubation under general anesthesia
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Department of Anesthesiology and Pain Medicine Anesthesia and Pain Research Institute Yonsei University
🇰🇷Seoul, Korea, Republic of