Prospective Registry of Radiation Exposure Measurement in Procedures Utilizing Fluoroscopy
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- AdventHealth
- 入组人数
- 150
- 试验地点
- 1
- 主要终点
- Degree of exposure measured by Dap meter and cumulative air KERMA
研究概览
简要总结
There has been increasing awareness regarding the risk of radiation exposure to patients and providers when performing procedures requiring fluoroscopic guidance.
详细描述
Fluoroscopy guidance is routinely used in many endoscopic procedures per standard-of-care practice and there is increasing effort to minimize the degree of radiation exposure to patients and providers during fluoroscopy usage. The current fluoroscopy machine used per standard-of-care practice at the Center for Interventional Endoscopy is the Eview machine (Omega Medical Imaging, Orlando, FL, USA). Recently, CA-100S technology (FluoroShield, Omega Medical Imaging) has been developed in an effort to further reduce the degree of radiation exposure to patients and provides. This technology is an additional component that can be fitted to the preexisting Eview fluoroscopy machine, in order to further filter radiation that has passed through the pre-existing machine. The investigators will be performing this study to determine the degree of radiation exposure to patients and providers when using the Eview fluoroscopy machine, with and without the FluoroShield radiation exposure reduction system.
There has been increasing awareness regarding the risk of radiation exposure to patients and providers when performing procedures requiring fluoroscopic guidance. In a prior study, the Eview machine, which is currently used for fluoroscopy guidance at the Center for Interventional Endoscopy, was shown to decrease, but not completely eliminate, radiation exposure when compared to C-arm type of fluoroscopy machines (GE Healthcare, Wauwatosa, WI, USA). Recently, the FluoroShield technology (Omega Medical Imaging) has been developed in an effort to further reduce the degree of radiation exposure to patients and provides. This technology is an additional component that can be fitted to the preexisting Eview fluoroscopy machines, in order to further filter radiation that has passed through the pre-existing machine.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •18 years and older
- •Having an endoscopy with fluoroscopy
排除标准
- •Less than 18 years of age
- •Not having an endoscopy with fluoroscopy
结局指标
主要结局
Degree of exposure measured by Dap meter and cumulative air KERMA
时间窗: 1 day
Measurement of the degree of radiation exposure to patients and providers when performing endoscopic procedures with fluoroscopy guidance, with and without the FluroShield radiation exposure reduction system will be measured. The data will be collected in microgray per meter squared (Dap meter) and milligray (cumulative air KERMA).
次要结局
未报告次要终点