Integrated Analysis in Recovery After Exercise With and Without Hydration.
- Conditions
- Healthy
- Interventions
- Other: Control protocolOther: Hydration protocol
- Registration Number
- NCT05179382
- Lead Sponsor
- Luiz Carlos Marques Vanderlei
- Brief Summary
This study aims to evaluate post-exercise recovery in healthy young men submitted to a prolonged exercise protocol of submaximal intensity with or without water intake, from the integrated analysis of autonomic (heart rate variability indices), cardiovascular outcomes (systolic blood pressure, diastolic blood pressure and heart rate) and respiratory (oxygen saturation and respiratory frequency). In addition, it will also be evaluated whether the proposed model is able to estimate the number of individuals undergoing hydration that have better recovery.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Male
- Target Recruitment
- 54
- Include healthy and male individuals, age between 18 and 25 years and physically active.
- Volunteers with at least one of the following characteristics will be excluded: smoking, use of drugs that influence the autonomic activity of the heart, alcoholics, people with known metabolic and/or endocrine disorders, and sedentary individuals, insufficiently active and very active.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description Control protocol Control protocol The control protocol will consist of an initial 10 minutes of rest, followed by 90 minutes of aerobic activity and 60 minutes of the final recovery. Hydration will not be allowed throughout the protocol. Hydration protocol Hydration protocol This intervention will consist of an initial 10 minutes of rest, followed by 90 minutes of aerobic activity and 60 minutes of the final recovery. In this protocol, volunteers will be hydrated with mineral water from the 15th minute of exercise until the end of recovery.
- Primary Outcome Measures
Name Time Method Autonomic Modulation - SD1 index Acute evaluation during interventions he data for this evaluation will be collected using a heart rate monitor that registers the heart rate beat by beat and provides information regarding the RR intervals. The SD1 index corresponds to the dispersion of points perpendicular to the line of identity of the ellipse obtained from the Poincaré plot. Expressed in milliseconds.
Blood Pressure Acute evaluation during interventions Will occur indirectly, using a stethoscope and an aneroid sphygmomanometer in the left arm. The indicated values will be registered in an individual form. To avoid errors in the determination of blood pressures in volunteers, a single evaluator will measure these variables throughout the experimental procedure. Data will be collected at the end of the 10 minutes of initial rest and at minutes 30, 60 and 90 during exercise on the treadmill, as well as will be collected at minutes 1, 3, 5, 7, 10, 20, 30, 40, 50 and 60 of recovery.
Peripheral oxygen saturation Acute evaluation during interventions Will be checked using a pulse oximeter. A pulse oximeter is a device that provides blood saturation readings, evaluating the absorption behavior of oxyhemoglobin and deoxyhemoglobin in relation to the lengths of red and infrared light. Data will be collected at the end of the 10 minutes of initial rest and at minutes 30, 60 and 90 during exercise on the treadmill, as well as will be collected at minutes 1, 3, 5, 7, 10, 20, 30, 40, 50 and 60 of recovery.
Autonomic Modulation - HF index Acute evaluation during interventions he data for this evaluation will be collected using a heart rate monitor that registers the heart rate beat by beat and provides information regarding the RR intervals. The HF index is the high-frequency component of the oscillatory components of heart rate variability, and ranges from 0.15 to 0.4 Hz.
Autonomic Modulation - SDNN index Acute evaluation during interventions The data for this evaluation will be collected using a heart rate monitor that registers the heart rate beat by beat and provides information regarding the RR intervals. The SDNN index corresponds to the standard deviation of all normal RR intervals recorded in a time interval, expressed in milliseconds.
Autonomic Modulation - rMSSD index Acute evaluation during interventions The data for this evaluation will be collected using a heart rate monitor that registers the heart rate beat by beat and provides information regarding the RR intervals. The rMSSD index corresponds to the root-mean square of differences between adjacent normal RR intervals in a time interval, expressed in milliseconds.
Heart Rate Acute evaluation during interventions The heart rate will be captured beat by beat using the Polar RS800CX frequency meter, equipment previously validated to capture this parameter. Data will be collected at the end of the 10 minutes of initial rest and at minutes 30, 60 and 90 during exercise on the treadmill, as well as will be collected at minutes 1, 3, 5, 7, 10, 20, 30, 40, 50 and 60 of recovery.
Autonomic Modulation - LF index Acute evaluation during interventions The data for this evaluation will be collected using a heart rate monitor that registers the heart rate beat by beat and provides information regarding the RR intervals. The LF index is the low-frequency component of the oscillatory components of heart rate variability, and ranges from 0.04 to 0.15 Hz.
Respiratory Rate Acute evaluation during interventions The measurements will be performed by counting the breaths for one minute without the volunteer being aware of the process, so that the usual breathing characteristics are not modified. Data will be collected at the end of the 10 minutes of initial rest as well as will be collected at minutes 1, 3, 5, 7, 10, 20, 30, 40, 50 and 60 of recovery.
Autonomic Modulation - SD2 index Acute evaluation during interventions The data for this evaluation will be collected using a heart rate monitor that registers the heart rate beat by beat and provides information regarding the RR intervals. The SD2 index corresponds to the dispersion of points along the line of identity of the ellipse obtained from the Poincaré plot. Expressed in milliseconds.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Universidade Estadual Paulista Júlio de Mesquita Filho
🇧🇷Presidente Prudente, São Paulo, Brazil