跳至主要内容
临床试验/NCT01750450
NCT01750450已完成不适用

Validation of Peripheral Pressure Volume Loops and Ultrasound-derived "Cardiac Power" by Comparison With Invasive Left Ventricular Pressure Volume Loops

University of Virginia1 个研究点 分布在 1 个国家目标入组 65 人开始时间: 2013年2月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
65
试验地点
1
主要终点
Correlation between left ventricular pressure volume area (PVA) and aortic PVA

研究概览

简要总结

The investigators will generate pressure-flow loops and pressure-volume loops from aortic and left ventricular pressure waveforms and Doppler (desc. aorta) flow waveforms and compare left ventricular to arterial pressure-flow and pressure-volume loops as well as to cardiac power from the USCOM 1A device. The goal of this study is to test the hypothesis that non-invasive estimates of cardiac pressure-volume work (derived from ultrasound-based measurements) correlate with invasive estimates.

详细描述

Extensive animal work by Suga et al. in the 1980s clearly demonstrate a relationship between left ventricular pressure volume area (PVA) and myocardial consumption of oxygen (MVO2).

PVA can be measured by combining radial artery pressures with ultrasound-derived estimates of aortic blood flow. Because the aorta and peripheral artery compartments are separated from the left ventricle by the aortic valve, the peripheral arterial pressures cannot perfectly approximate left ventricular pressures. However, because the majority of variation in the pressure volume loops is made up of changes in height and width (changes in the left ventricular end-diastolic curve are, by contrast, relatively small), both of which can be readily detected by changes in the peripheral arterial blood pressure tracing, this loss of information may be clinically insignificant.

USCOM, has developed a portable suprasternal Doppler probe (model 1A) capable of estimating left ventricular stroke volume; a unique feature of this device is its ability to utilize both stroke volume, heart rate, and mean arterial pressure in an attempt to measure cardiac power. This device has not been validated against invasive estimates of cardiac power.

Knowledge of MVO2 would be a useful clinical variable but is not widely available. The ability to non-invasively estimate MVO2 intraoperatively would give anesthesiologists the ability to measure the effect of hemodynamic interventions on myocardial consumption of oxygen and, when combined with stroke volume, estimate myocardial efficiency. Non-invasively estimates of MVO2 may also allow cardiologists a novel means of assessing the myocardium of patients with cardiovascular disease.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult (18 or older)
  • Undergoing left heart catheterization

排除标准

  • Unable to visualize ascending aorta using ultrasound

结局指标

主要结局

Correlation between left ventricular pressure volume area (PVA) and aortic PVA

时间窗: day of procedure

The primary hypothesis of this study is that the slope of the regression line between left ventricular pressure volume area (PVA, as determined by simultaneous measurement of aortic outflow and left ventricular pressures) and aortic PVA (as determined by simultaneous measurement of aortic outflow and radial artery pressure) is not zero. The null hypothesis is that the probability that the slope of the regression line is different from a line with a slope of 0 is greater than 5%.

次要结局

未报告次要终点