Agreement Test of Intravascular Volume Assessment Between Inferior Vena Cava (IVC) Diameter and Vascular Pedicle Width (VPW)
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 35
- 试验地点
- 2
- 主要终点
- Intravascular volume measurement
研究概览
简要总结
This study aimed to know the consistency of intravascular volume measurement using USG of IVC compared to VPW chest x-ray
详细描述
Approval from Ethical Committee of Faculty of Medicine Universitas Indonesia was acquired prior conducting the study. Validation and reliability test were done for USG operators by assessing IVC in 20 patients supervised by intensivists. Subjects were given informed consent before participating in the study. Subjects underwent the chest x-ray examination with supine position. The measurement of VPW was done by radiologists, considered normal if the value is 53 ± 5 mm, overload if VPW > 71 mm. The subjects then underwent the IVC diameter measurement using USG Philips En Visor C, with transthoracal subcostal approach. The result is considered normal if IVC diameter is 1.5 - 2.5 cm and overload if >2.5 cm, otherwise the subjects is excluded. If the IVC can not be done, subjects will be excluded.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- Single (Investigator)
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult non-intubated patients aged 18-65 in ICU or resucitation room
- •BMI 18.5-35 kg/m2
- •Signed informed consent of the patient to be included in the study
排除标准
- •BMI >35, intubated
- •History of thoracic or heart surgery
- •History of external and internal radiation
研究组 & 干预措施
Inferior vena cava (IVC) diameter
subjects underwent IVC diameter measurement after VPW measurement
干预措施: Inferior vena cava (IVC) diameter using USG (Diagnostic Test)
Vascular pedicle width (VPW)
Supine chest x ray was done and the VPW is assessed by radiologists.
干预措施: Vascular pedicle width (VPW) (Diagnostic Test)
结局指标
主要结局
Intravascular volume measurement
时间窗: IVC is measured 30 minutes after VPW
Measured by VPW and IVC diameter using USG
次要结局
未报告次要终点
研究者
Amir S Madjid
Anesthesiologist
Indonesia University