Atrial Electromechanical Interval and Pulse Wave Velocity in the Prediction of Recurrence of Atrial Fibrillation In Patients Undergoing Successful Electrical Cardioversion to Sinus Rhythm
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 129
- 试验地点
- 1
- 主要终点
- Recurrence of Atrial Fibrillation
研究概览
简要总结
This study aims to evaluate the utility of the atrial electromechanical interval and pulse wave velocity in the prediction of recurrence of atrial fibrillation among patients who underwent successful direct current cardioversion for atrial fibrillation.
详细描述
This will be a prospective cohort study designed to evaluate the value of atrial electromechanical interval and pulse wave velocity in the prediction of recurrence of atrial fibrillation among patients with atrial fibrillation with successful direct-current cardioversion to sinus rhythm.
Should cardioversion be successful, a limited 2D echocardiogram will be done and the following information will be measured: atrial electromechanical interval, left atrial volume, left atrial size, ejection fraction, and maximal A-wave transmitral Doppler flow velocity. The presence of left ventricular hypertrophy and valvular heart disease will be recorded. In addition, baseline clinical information including age, gender, medications, presence of HTN, DM, CAD, stroke, and prior history of atrial fibrillation will be obtained.
Radial artery applanation tonometry and pulse wave analysis will be used to calculate a central aortic pressure and other parameters using commercially available SphygmoCor® system. Central aortic pressures will be obtained immediately following measurement of brachial artery pressures. Patients will be seated for 5 minutes in a quiet room after which time blood pressure will be measured over the brachial artery three times at 5 minute intervals. The mean of the last two measurements will be recorded as representative of the brachial artery pressure. After the last measurement, radial artery pressure waveforms of the same arm will be sampled over 10 seconds with a Millar tonometer and calibrated to the average brachial pressure. Waveforms will be processed with dedicated software (SphygmoCor® version 7, AtCor). The software will be used to calculate an averaged radial artery waveform and to derive a corresponding central aortic pressure. Aortic pressure waveforms will be subjected to further analysis by the SphygmoCor® software to identify the time to the peak/shoulder of the first and second pressure wave components (T1, T2) during systole. The pressure at the peak/shoulder of the first component sill be identified as P1 height (outgoing pressure wave) and the pressure difference between P1 and the maximal pressure during systole (∆P or augmentation) will be identified as the reflected pressure wave occurring during systole. Augmentation index (AIx), defined as the ratio of augmentation to central pulse pressure, will be expressed as the percentage: AIx = (∆P/PP) x 100, where P is pressure and PP is pulse pressure. Pulse pressure amplification (PPA) will be expressed as the ratio of central pulse pressure (CPP) to peripheral (brachial) pulse pressure (PPP): PPA = PPP/CPP
Information will be recorded and the patients will be followed by their respective cardiologists and evaluated for recurrence of atrial fibrillation within 6 months.
Primary endpoint for this study is clinical recurrence of atrial fibrillation or 6 month time frame of sustained maintenance of sinus rhythm whichever comes first.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 19 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age greater than or equal to 19 years of age
- •History of atrial fibrillation with successful cardioversion to sinus rhythm
- •Informed consent to participate in the study
排除标准
- •Failure of cardioversion to sinus rhythm
- •Use of anti-arrythmic drug therapy
- •Refusal to participate in the study
结局指标
主要结局
Recurrence of Atrial Fibrillation
时间窗: 6 months
次要结局
未报告次要终点
